background image

Parts

Ref.

Ref.

Ref.

Part

Part

Part

Description

Description

Description

Qty.

Qty.

Qty.

901

16P919

SHAFT, agitator, upper

1

902

16U219

HOUSING, agitator

1

903

122772

SEAL, PTFE

1

904

15Y360

SPACER, shaft, agitator

1

905

122774

BEARING, 3/4 ID x 1–3/4
OD

2

906

16P920

HOUSING, bearing, agitator

1

907

125303

SCREW, SHCS, 5/16–18 x
0.75

2

908

112222

SCREW, socket cap head

4

909

122776

RING, retaining, external,
0.75

1

910

122761

HOUSING, alignment, hub

1

911

112760

COUPLING, alignment, disk,
TPE

1

912

16P922

BRACKET, adapter, agitator

1

913

C19209

WASHER, lock

8

914

101682

SCREW, socket cap head

4

915

181794

GEAR, reducer

1

916

16P923

COUPLER, adapter

1

917

100828

COUPLING, flexible

1

918

16T063

COLLAR, mounting

1

919

116940

SCREW, SHCS, 5/16–18

2

Ref.

Ref.

Ref.

Part

Part

Part

Description

Description

Description

Qty.

Qty.

Qty.

920

181849

COLLAR

1

921

101118

SCREW

2

922

111310

MOTOR, air, rotary

1

923

115841

FITTING, elbow

1

924

129069

MUFFLER, air, exhaust

1

929

17Z460

LABEL, warning

1

930

17R088

LABEL, warning,
multi-language (not shown)

1

931

16A614

LABEL, notice

1

932

120376

KEY, square, .188 x .62

1

2

Apply low strength threadlocker.

3

Apply medium strength threadlocker.

5

Leave a 0.015 in gap between each half of
couplings.

7

Remove set screw supplied with coupling and
replace with set screw (907).

8

Open side of u-cup seal (903) must face down
inside housing (902).

Replacement safety labels, tags, and cards

are available at no cost.

20

3A4032D

Summary of Contents for Xtreme-Duty 25A598

Page 1: ...allon gallon gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Importan...

Page 2: ...e 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Maintenance 15 Agitator Fasteners 15 Agitator Blades 15 Air Motor M...

Page 3: ...Mounting Support Support Support Feed Feed Feed Pump Pump Pump Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit H...

Page 4: ...or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use...

Page 5: ...ZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using...

Page 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Page 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Page 8: ...the ground wire G to the ground connector GC on the side of the agitator and or drum cover Connect the clamp end of the ground wire to a true earth ground For an additional ground wire and clamp order...

Page 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Page 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Page 11: ...RAISE NN Ref Ref Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agi...

Page 12: ...ther end to the inlet of the proportioning system or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has...

Page 13: ...the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make sure all valves are in t...

Page 14: ...revent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance Fi...

Page 15: ...n become electrostatically charged when stirred or blended Dried material could allow static buildup and interfere with grounding To prevent fire and explosion ground equipment and do not allow materi...

Page 16: ...ator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE Not lubricating the air motor will cause air motor failure Install air line lubricator and air line filter If an air line lubricator is not inst...

Page 17: ...in 1 18 155699 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 20 16F151 FITTING connector 1 21 17M563 BRACKET guard cou...

Page 18: ...9 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 20 16F151 FITTING connector 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 21 17M563 BRACKET guard coupling 1 22 15...

Page 19: ...lvent and paint fumes can ignite or explode Material can become electr ostatically char ged Use equipment only in well ventilated ar ea Eliminate all ignition sour ces Gr ound all equipment in work ar...

Page 20: ...16P923 COUPLER adapter 1 917 100828 COUPLING flexible 1 918 16T063 COLLAR mounting 1 919 116940 SCREW SHCS 5 16 18 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 920 181...

Page 21: ...ription 25A599 25A599 25A599 25A600 25A600 25A600 25A601 25A601 25A601 25A602 25A602 25A602 25A603 25A603 25A603 25A604 25A604 25A604 Qty Qty Qty 101 25A598 Xtreme Duty agitator X X X X X X 1 102 17J0...

Page 22: ...0 1 sst X 1 109 119922 FITTING nipple 3 4 in X X X X X 1 110 248829 KIT regulator feed pump X X X X X 1 111 256653 KIT fluid strainer X X X X X 1 112 217382 HOSE 3 4 in 10 ft X X X X X 1 113 128689 PL...

Page 23: ...mum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agitator Blades 13 75 in 349 mm...

Page 24: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: