Prime Empty System
28
3A4381M
5. Open the motor shutoff valve (CA). Then slowly
open the motor pressure regulator (CB).
6. Dispense fluid into the containers until clean fluid
comes out of the A and B recirculation lines.
7. Decrease air pressure. Close the motor shutoff
valve (CA).
8. Move the recirculation lines (U) back to the correct
hopper (J).
9. If using heaters, heat fluid throughout system before
Recirculate Prior to Spraying or
Re-Prime After a Pump Runs Dry
WLE
B
A
CB
CA
WLD
WLE
CA
WLE
8
-