![background image](http://html.mh-extra.com/html/graco/therm-o-flow-t7-series/therm-o-flow-t7-series_instructions-manual_2251693017.webp)
Operation
309832D
17
Setting auxiliary controls
Auxiliary input selection is accomplished on per channel
basis and can only be accessed when the control is in
standby mode.
Setting standby timer
Setting the standby will turn off the tank, hose, and
applicator heat for a selected amount of time. When the
standby time is complete, the tank settings automatically
resume to previous set temperatures and heating con-
tinues.
1.
Press the standby toggle
.
2.
Press the loop select up/down
to select appro-
priate auxiliary channel
.
3.
To activate or deactivate selected auxiliary, press
the loop select on/off
. LEDs to the left of the
selection will show GREEN if on.
4.
To resume operation, press the standby
toggle .
1.
Press the standby
toggle.
2.
Press temperature increment/decrement
to
increase or decrease time. Set time will appear in
the set temperature display. You must enter a mini-
mum of five minutes for standby time.