![background image](http://html.mh-extra.com/html/graco/therm-o-flow-t7-series/therm-o-flow-t7-series_instructions-manual_2251693024.webp)
Repair
24
309832D
F
IG
. 5: Connecting hose
3.
Allow tank unit to cool before repairing.
4.
Disconnect applicator from hose. See appropriate
applicator manual for instructions.
S
R
K
P
J
5.
Remove bayonet ring from the electrical connector.
6.
. 5. Pull electrical connector (K) from the
hose electrical receptacle (S).
7.
. 5. Using an 11/16 in. wrench, remove
hose (J) from the fluid outlet fitting (P).
8.
Replace hose. To reconnect hose, see
Connecting
Hose