![background image](http://html.mh-extra.com/html/graco/therm-o-flow-t7-series/therm-o-flow-t7-series_instructions-manual_2251693015.webp)
Operation
309832D
15
Starting the hot melt system
Adjusting panel controls
Refer to the material manufacturer’s specifications for
correct operating temperatures.
Temperature Range Chart
The temperature range chart shows each range number
and its corresponding tank, hose, and applicator tem-
perature range.
Setting temperature to
Fahrenheit (°F) or Celsius (°C)
Selecting tank
Setting temperature range
The temperature range number reflects the setting for
the tank, hose, and applicator. See
, page 15.
1.
Plug in hot melt system.
2.
Turn on/off switch (R) ON. See F
Range
Tank Temperature
Hose and
Applicator
Temperature
1
120 to 195°F
49 to 91°C
150 to 225°F
66 to 107°C
2
160 to 235°F
71 to 113°C
190 to 265°F
88 to 129°C
3
200 to 275°F
93 to 135°C
230 to 305°F
116 to 152°C
4
240 to 315°F
116 to 157°C
270 to 345°F
132 to 174°C
5
280 to 355°F
138 to 179°C
310 to 385°F
154 to 196°C
6
320 to 395°F
160 to 202°C
350 to 425°F
177 to 218°C
1.
Use the loop select up/down
to select tank
. The LED to the left of the device should
show GREEN.
2.
Once the tank device is selected and LED is
GREEN, press the loop select up
four times.
The range indicator digit will begin flashing.
3.
Press the loop select on/off
. Notice the actual
temperature display
. If the temperature
in the display is lower, it is set to °C. If the tempera-
ture in the display is higher, it is set to °F.
Use the loop select up/down
to select
tank
. The LED to the left of the device indicates
selection.
1.
Select the tank
and press the loop select up
four times. The range indicator digit will begin
flashing.
2.
Press the set temperature increment or decrement
to set appropriate range digit. See
, page 15. This will only raise or
lower the range digit value one level. To change the
value, repeat steps 1 and 2.