Cause
Cause
Cause
Solution
Solution
Solution
Reduce flow rate.
Increase temperature of accessory upstream.
Faulty accessory heater measure resistance between
heater leads.
Change Low Temp Alarm Offset.
T1
_
Low Temp. Unit
_ Zone _
Alarm
Zone
temperature
too low
Replace accessory.
Reduce flow rate.
Change Low Temp Deviation Offset.
T2
_
Low Temp. Unit
_ Zone _
Deviation
Zone
temperature
too low
Add zone (temperature) upstream.
Change High Temp Deviation Offset.
T3
_
High Temp.
Unit _ Zone _
Deviation
Temperature
reading has
risen too high
Verify setpoint upstream is not hotter than this zone’s
setpoint.
Ensure inlet and outlets are not obstructed.
T4C#
AWB
Temperature
Runaway
Transformer
Alarm
Cooling fan
not working
or inlet is
blocked/dirty
Verify fan is plugged in.
Ensure inlet and outlets are not obstructed.
T4M#
AWB High
Transformer
Temp
Alarm
Transformer
Temperature
is too High
Verify fan is plugged in.
Change High Temp Alarm Offset.
T4
_
High Temp.
Unit _ Zone _
Alarm
Temperature
reading has
risen too high
Verify setpoint upstream is not hotter than this zone’s
setpoint.
Check RTD wiring and harness/connector integrity.
T6
_
Sensor Err. Unit
_ Zone _
Alarm
Bad RTD
Reading
Replace RTD.
T6C#
AWB Invalid
Thermistor
Reading
Alarm
Transformer
thermistor
temperature
is incorrect
Verify thermister is securely connected to J7 of the
AWB. Replace transformer if necessary.
Check fuses on MZLP connected to that Zone.
Check wiring to device.
T8V _
No Temp. Rise
Unit _ Zone _
Alarm
Temperature
reading does
not change.
Check heater resistance on device.
V1I#
Low CAN
Voltage, MZLP
_
Alarm
Bad or
overloaded
power supply
Verify power supply voltage is 24 VDC. If voltage is
low, disconnect the power lines and re-check voltage
reading. If voltage is still low, replace power supply. If
voltage is correct after disconnecting the power lines.
Connect items one at a time until the voltage drops
to isolate the bad module.
V1M#
Low Voltage
Line AWB, Unit
_
Deviation
The voltage
to the AWB
is below
threshold
Verify transformer voltage top matches incoming
voltage. Verify incoming voltage is correct.
V4I#
High CAN
Voltage, MZLP
_
Alarm
Bad or
overloaded
power supply
Verify power supply voltage is 24 VDC. If voltage is
high, replace power supply unit.
334130D
41
Summary of Contents for Therm-O-Flow 200
Page 48: ...Repair Figure 28 48 334130D...
Page 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Page 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Page 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Page 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Page 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Page 68: ...Parts 68 334130D...