Troubleshooting
Troubleshooting
Troubleshooting
Light
Light
Light Tower
Tower
Tower (Optional)
(Optional)
(Optional)
Signal
Signal
Signal
Description
Description
Description
Red Light Off
If green light is also off, system power may be off or system operating mode is Inactive. If
green is on or flashing, there are no active errors.
Red Light On
User interaction required — alarm, system is shut down
Red Light
Flashing
User interaction required — advisory, deviation, or system is in a state that could prohibit
dispensing.
Green Light Off System is inactive
Green Light On System is ready to dispense. The heat and pump are on.
Green Light
Flashing
System will be ready to dispense in time without user interaction (heat on, pump off, and
temperature control zones have not reached set point)
334130D
37