To connect a hose to a fluid control device or heated
manifold.
1.
Install fitting and heated hose onto pump outlet
with the large electrical connector side toward
the system. Use 2 wrenches to tighten hose.
Torque to 45 ft-lbs (61 N•m).
Note
See
for
available fittings and heated hoses.
Figure 9
2.
Wrap exposed fittings on the pump outlet with
Nomex insulation and secure insulation using
fiberglass tape.
3.
Connect large heated hose connector to MZLP.
4.
Repeat for any remaining channels.
5.
For proper operation, cables must be plugged
into zones 1–2 and 3–4 at all times.
6.
Install cap on any unused MZLP electrical
connectors.
7.
Connect the small 8 pin connector from the
heated hose to the fluid control device or heated
manifold.
Figure 10 Heated Manifold 243697
Note
The heated manifold (part
no. 243697) shown. See
, for
available manifolds and fluid control
devices.
8.
Use 2 wrenches to tighten hose. Torque to 45
ft-lbs (61 N•m).
9.
To connect multiple devices, see
Connect Multiple Devices, page 18
.
334130D
17
Summary of Contents for Therm-O-Flow 200
Page 48: ...Repair Figure 28 48 334130D...
Page 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Page 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Page 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Page 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Page 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Page 68: ...Parts 68 334130D...