Screen
Screen
Screen Components
Components
Components
1.
Screen Order
2.
Current date and time
3.
Operating Mode
4.
Faults, Status
5.
MZLP Plug Identifier
6.
Zone Setpoint Temperature
7.
Zone Actual Temperature
Operating
Operating
Operating Mode
Mode
Mode
Description
Description
Description
Component
Component
Component Status
Status
Status
System Off
The system does not have power.
• No system status indicator LED on the
ADM
• No heat
• Pump is off
Inactive
The heating system and pumps are
disabled.
• Yellow system indicator LED on the
ADM
• No heat
• Pump is off
Warm Up
The system is heating the material to the
setpoint temperature.
• Flashing green system status indicator
LED on the ADM
• Heat is increasing to setpoint
temperature
• Pump is off
Heat Soak
Heat zones are all at temperature.
Material is soaking for a user specified
amount of time.
• Flashing green system status indicator
LED on the ADM
• Heat is at setpoint
• Material is absorbing more heat
• Pump is off
• Heat soak counter counts down on the
Home screen.
Ready
All enabled zones are at setpoint
temperature. The air motor does not have
power.
• Flashing green system status indicator
LED on the ADM
• Heat is at setpoint
• Pump is off
Active
The system is ready to dispense.
• Solid green system status indicator
LED on the ADM
• Heat is at setpoint temperature
• Pump is on
334130D
13
Summary of Contents for Therm-O-Flow 200
Page 48: ...Repair Figure 28 48 334130D...
Page 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Page 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Page 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Page 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Page 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Page 68: ...Parts 68 334130D...