Warnings

313291D

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back 
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where 
applicable.

WARNING

WARNING

WARNING

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent 
fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static arc). 

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment 
until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable regulations.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and 
cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, 
checking, or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

Always wear impervious gloves when spraying or cleaning equipment.

Summary of Contents for SHARPE 24A555

Page 1: ...ons requiring portability small batches or frequent color changes 50 psi 350 kPa 3 5 bar Maximum Working Pressure Model 24A555 Series A shown Basic portable pressure tank Model 24A557 Series A with du...

Page 2: ...Setup 5 Operation 6 Pressure Relief Procedure 6 Fill the Tank 6 Adjust the Air Regulators 6 Vertical and Horizontal Reach 6 Cleaning and Maintenance 7 Technical Data 7 Parts 8 Sharpe 1 Year Limited W...

Page 3: ...component See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read fluid and solvent manufac...

Page 4: ...uity To maintain grounding continuity when flushing or relieving pressure hold metal part of the spray gun firmly to the side of a grounded metal pail then trigger the gun WARNING WARNING WARNING WARN...

Page 5: ...on the tank cover 5 Assemble the air regulator 9 See page 8 for Model 24A555 single regulated tank See page 9 for Model 24A557 dual regulated tank 6 Screw the assembled regulator into the swivel union...

Page 6: ...cause the gasket 1c to squeeze out The gasket is needed to properly seal the cover and tank Adjust the Air Regulators Turn the air regulator T handle counterclockwise all the way to off Turn on the ma...

Page 7: ...of the tank and equipment with a solvent dampened rag 11 Remove the riser tube E and clean it thoroughly 12 Keep the pressure relief valve 1b clean and in working order The relief valve is preset and...

Page 8: ...l ene not shown 5 pack of tank liners 25 pack of tank liners 1 1 1b 103996 VALVE pressure relief 50 psi 350 kPa 3 5 bar 1 1c 244953 GASKET cover polyethylene package of 3 1 2 156823 UNION swivel 1 9 U...

Page 9: ...ck of tank liners 25 pack of tank liners 1 1 1b 103996 VALVE pressure relief 50 psi 350 kPa 3 5 bar 1 1c 244953 GASKET cover polyethylene package of 3 1 2 156823 UNION swivel 1 9 U10004 REGULATOR ASSE...

Page 10: ...ainder of the original warranty period Sharpe or its authorized service representatives must perform all warranty repairs Any repair to the product by unauthorized service representatives voids this w...