Electro-pneumatic Control Panel Display Screens
Outputs
Outputs
Outputs from
from
from the
the
the Allen
Allen
Allen-
-
-Bradley
Bradley
Bradley Controller
Controller
Controller
Variable
Variable
Variable Name
Name
Name
Data
Data
Data Type
Type
Type
Possible
Possible
Possible
Values
Values
Values
Notes
Notes
Notes
AB2BR_rec_airAssistPres-
sure_psi
REAL
REAL
Corresponds to bit 9 in the
AB2BR_networkOverwriteBitfield
variable. Units in psi.
AB2BR_rec_primeTime_s
INT
INT
Corresponds to bit 10 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_emptyTime_s
INT
INT
Corresponds to bit 11 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_sealDeflateTime_s
INT
INT
Corresponds to bit 12 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_airAssistTime_s
INT
INT
Corresponds to bit 13 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_batchAmount-
Mass_lbs
REAL
REAL
Corresponds to bit 14 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this
value. Units in pounds.
AB2BR_rec_batchAmountVol-
ume_gal
REAL
REAL
Corresponds to bit 15 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this
value. Units in gallons.
AB2BR_batchEnabled
BOOL
TRUE, FALSE
Corresponds to bit 16 in the
AB2BR_networkOverwriteBitfield
variable. This switches between
an "Auto" sequence and a "Batch"
sequence.
AB2BR_networkOverwriteBit-
field
DINT
Bitfield
This variable is used as a bitfield,
where every denoted output variable
has a corresponding bit. If the remote
PLC intends the STU to read the
value in from the Ethernet/IP network
interface and make it active in the
system, the corresponding bit for
that variable must be set to TRUE
in this bitfield. When a bit is set to
TRUE, any value changes from the
STU's touchscreen (including loading
a new recipe) will be overwritten by
the network value, unless “Override
Remote” is checked on the STU
Network screen. When a bit is FALSE,
the STU system ignores the network
value.
62
3A5416L