Model 3150 Performance Chart
310622ZAL
49
Model 3150 Performance Chart
Test Conditions: Pump tested in water with inlet submerged
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3.Follow left to scale to read fluid outlet pressure.
To find Pump Air Pressure
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve.
3. Follow left to scale to read fluid outlet pressure.
3150 3A Performance Chart
150
(4.2)
125
(3.5)
100
(2.8)
75
(2.1)
50
(1.4)
25
(0.7)
0
0
20
(76)
40
(152)
60
(227)
80
(303)
100
(379)
120
(454)
140
(531)
160
(606)
20
(1.4, 0.14)
40
(2.8, 0.28)
60
(4.2, 0.42)
80
(5.5, 0.55)
100
(7, 0.7)
120
(8.4, 0.84)
Air Consumption
scfm (m
3
/min)
Fluid Outlet Pressure
psi (bar, MPa)
TI8644a
TI8645a
Fluid Flow
gpm (lpm)
Summary of Contents for SaniForce 1590 3A