background image

Operation 

12

3A8597B

Operation

Prime the ProMix PD TSL Auto Lube 
System

1.

Fill the G3 Pro fluid reservoir with Graco Throat Seal 
Lubricant (TSL). (See the G3 Pro Automatic 
Lubrication Pump manual, “Filling Oil Unit”.)

2.

To prime the system for the first time

 - 

a.

Set the ON Time to 15 minutes. (See G3 Pro 

Automatic Lubrication Pump manual, 

“Instructions/ON Time/Programming ON Time”.)

b.

Prime the G3 Pro pump and start the pump 

using the Manual Run button. (See the G3 Pro 

Automatic Lubrication Pump manual, “Priming” 

and “Control Panel Overview”.)

c.

Observe the TSL fluid flow through the main line 

from the G3 Pro pump to the CSP divider valve, 

and then out to each lube point and into the 

waste container. It will take several minutes to 

fill out the fluid lines.

d.

Repeat the Manual Run cycles as needed to 

fully prime and fill all lines.

ON/OFF Time Guidelines

Based on each installation and application ON times 
and frequency of automatic lubrication needs will vary. If 
you have experienced rapid contamination of a ProMix 
PD pump TSL or a short pump seal life without an Auto 
Lube system installed, it is recommend that you start 
with a relatively high ON time and frequency (lower OFF 
time between ON time cycles). Monitor the TSL waste 
for contamination and adjust accordingly. 

Pump seal life varies greatly depending on the types of 
fluid used, though one of the most important 
preventative maintenance steps that can extend the 

pump life is regular and proper TSL lubrication. The TSL 
maintains a barrier to slow the process of paint drying or 
catalyst reacting with moisture in the air and 
crystallizing. Replacing stagnant TSL with fresh TSL 
clears the contamination away from the seal/rod 
interface area which then slows the wear process and 
leads to longer seal life.

NOTE: 

See 

Table 2:

 

ON Time per Lube Point

, page 

13, for recommended ON/OFF Times for your ProMix 
PD TSL Auto Lube system. A good starting point is to 
provide 2 cc per lube point of the TSL per hour. On a 
new installation, closely monitor the condition of the 
waste TSL for any contamination and adjust the 
lubrication amount up or down as needed. The G3 Pro 
pump will continue to run the programmed ON/OFF 
cycle times when the unit is powered regardless if 
ProMix PD operation is occurring or not (e.g. off shift or 
weekends). Shut power off to the G3 Pro pump if you do 
not want automatic fresh TSL dispensing to continue. 
When powered is restored the pump will resume the 
cycle with the same amount of time remaining in the 
cycle as when the power was turned off (unless you 
have the Prelube feature enabled on the G3 Pro pump). 

Monitor the G3 Pro fluid reservoir level and replenish 
with TSL before it runs low. Running the unit out of fluid 
supply will allow air to enter the fluid lines which can 
introduce moisture (humidity) and cause catalyst to cure 
and damage the ProMix PD u-cup seals. If air is 
introduced into the fluid stream repeat the priming 
procedure above until all air is purged clear of the 
ProMix PD throat cartridges.   A low level detection kit is 
available as an accessory for the G3 Pro pump.

G3 Pro pump volumetric output is approximately 4 
cc/min. Output flow rate is dependent on the fluid 
viscosity and the pressure. For a low pressure 
application with the TSL lubricant, the fluid’s actual 
volume output will be slightly higher, but consistent over 
time. Therefore, use 

Table 2:

 

ON Time per Lube Point

 

as a guide for initial timer settings.

Summary of Contents for ProMix PD

Page 1: ...professional use only Not approved for use in explosive atmospheres or hazardous classified locations See page 3 for model information including maximum working pressure Important Safety Instructions...

Page 2: ...Kit Offerings 18 Expansion Kit Installation 19 Accessories 19 Technical Specifications 19 California Proposition 65 19 Graco Standard Warranty 20 Related Manuals Manual in English Description 332298 G...

Page 3: ...0 4 14 41 4 Kit PD TSL Auto Lube 4 point 2 pump 24Z505 8 outlet w indicator plus 4 17L651 doubling plugs 1 25U419 600 4 14 41 4 Kit PD TSL Auto Lube 6 point 3 pump 24Z504 6 outlet w indicator 1 25U420...

Page 4: ...roper grounding setup or usage of the system can cause electric shock Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment Connect...

Page 5: ...th genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and...

Page 6: ...gular supply of fresh TSL helps flush away contaminates that would otherwise crystallize or harden and cause reduced pump u cup seal life Typical Installation This following figure FIG 1 Typical ProMi...

Page 7: ...rod cover See FIG 4 for details These parts provide secondary protection below the primary catalyst throat cartridge area This secondary protection keeps the pump rod flooded in TSL and provides the...

Page 8: ...NY outlet port will completely restrict fluid flow to all ports The upstream pressure will increase until the pressure relief valve at the G3 Pro pump outlet opens Refer to the CSP Valve manual for al...

Page 9: ...shooting If there is a blockage downstream of the CSP valve in any of the outlet lines the valve and the indicator will stop cycling Table 1 CSP Valve Port Usage Model Outlet Fitting 6 Port Usage Doub...

Page 10: ...skets 16 as necessary 5 Fill the TSL Reservoir and bleed air from the lower rod to ensure the rod remains wetted during operation See Plumbing page 10 As the pump cycles the pump displaces TSL from th...

Page 11: ...ges FIG 5 and the parts diagram on page 16 have three ports 1 Install one of the push to connect 10 32 fittings 10 for the TSL fluid line from the CSP valve 8 2 Install one of the barb fittings 17 for...

Page 12: ...gnant TSL with fresh TSL clears the contamination away from the seal rod interface area which then slows the wear process and leads to longer seal life NOTE See Table 2 ON Time per Lube Point page 13...

Page 13: ...4 0 7 0 4 7 3 5 2 8 2 3 2 0 1 8 1 6 1 4 1 3 8 32 0 16 0 8 0 5 3 4 0 3 2 2 7 2 3 2 0 1 8 1 6 1 5 9 36 0 18 0 9 0 6 0 4 5 3 6 3 0 2 6 2 3 2 0 1 8 1 6 10 40 0 20 0 10 0 6 7 5 0 4 0 3 3 2 9 2 5 2 2 2 0 1...

Page 14: ...om the rod guard and bearing cartridge eliminating wet air contamination during the TSL replacement process 1 Follow the pressure relief procedure in your ProMix PD Operation manual Shut off the PD un...

Page 15: ...may cause the lines to develop leaks or separate from the barb fitting Fluid pressure in the TSL line can be caused by either of the following The rod guard displacement flow volume through the bearin...

Page 16: ...3 17 16 15 11 1 3 4 2 5 5 8 9 6 10 18 7 7 14 8 9 9 9 5 6 7 12 7 7 6 7 6 7 18 18 17 25U418 25U420 25U417 25U419 See Table 1 CSP Valve Port Usage page 9 for specific outlet fitting and doubling plug loc...

Page 17: ...tee 1 8 nptf x 1 8 nptm 1 1 1 1 4 563375 VALVE relief 1 8 npt 600 psi 1 1 1 1 5 17L653 FITTING ptc 1 4 in Tube x 1 8 npt 2 2 2 2 6 17L440 FITTING ptc 1 4 in CSP outlet 2 4 6 8 7 18D411 TUBE nylon 1 4...

Page 18: ...24Z510 CSP 18 outlet NPT w indicator 24Z511 CSP 20 outlet NPT w indicator 24Z512 CSP 22 outlet NPT w indicator Step 3 Order the required number of 2 point fluid connect kits to make up the additional...

Page 19: ...cal Specifications See also the G3 Pro Automatic Lubrication Pump and CSP Valve manuals California Proposition 65 Part Kits 206996 Fluid TSL 1 Gallon 206995 Fluid TSL 1 Quart ProMix PD Proportioner Pl...

Page 20: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Reviews: