Troubleshooting
◆
ProMix™ II Alarms
310653D
11
Troubleshooting
ProMix™ II Alarms
The ProMix™ II has alarms to alert you of a problem
and prevent off-ratio spraying. If an alarm occurs, opera-
tion stops and the following occurs:
•
A red LED illuminates steadily or flashes on the
Operator Station.
•
Operator Station displays an alarm E-Code, E1 to
E9.
•
Alarm sounds.
•
Status bar on the EasyKey™ Display shows the
alarm E-Code with a description.
Alarms E-Codes
To Clear Alarm and Restart
Except for Potlife Exceeded (E3) Alarm and Purge Error
(E2) Alarm, all alarms can be cleared by pressing the
Error Clear
key on the Operator Station.
To clear Pot Life Exceeded alarm, the system must be
purged. Press the Purge
key on the Operator Sta-
tion. The system purges until the preset purge time is
complete. Refer to purging procedure in ProMix™ II
Operation manual.
For Additional Information
See ProMix™ II Operation manual for additional alarm
troubleshooting information.
WARNING
Follow Pressure Relief Procedure, page 8, before
cleaning, checking, or servicing equipment. Read
warnings, page 6.
CAUTION
Do not use the fluid in the line that was dispensed off
ratio as it may not cure properly.
Operator Station
E-Code
Red LED
Description
E-Code
Communication Error
E1
Purge Error
E2
Potlife Exceeded Alarm
E3
Ratio Alarm
E4
Overdose Alarm
E5
Dose Time A Alarm
E6
Dose Time B Alarm
E7
Autodump Complete Alarm
E8
EasyKey in Setup Mode
E9
When an alarm occurs, determine the E-Code
before clearing it. You can use the EasyKey™
Report screen (F
. 2) to view the last 10 alarms
with date and time stamps.
F
IG
. 2: Setup Mode - Report Screen