Electrical
313881C
21
Connect Power Supply Module
to ProMix 3KS Fluid Station
1.
Connect one end of the 50 ft (15.2 m) Fluid Station
Power Cable (Part No. 123271, red color coded) to
the Power Supply Module I/S Power connector
. See F
2.
Connect the other cable end to the ProMix 3KS
Fluid Station Control connector
(J3). See
. 15.
Connect Booth Control to
ProMix 3KS Fluid Station
NOTE: The booth control is supplied with ProMix 2KS
manual systems. Disconnect and discard the 50 ft (15.2
m) gray cable connecting the booth control to the ProMix
2KS fluid station.
Connect the 50 ft (15.2 m) Booth Control Cable (Part
No. 123280, yellow color coded) from the Booth Control
to the ProMix 3KS Fluid Station connector
(J1).
Connect Color Change Module
to ProMix 3KS Fluid Station
NOTE: Disconnect and discard the 3 ft (0.9 m) gray
cable (supplied with the ProMix 2KS system) connecting
the color change module to the ProMix 2KS fluid station.
Connect the 6 ft (1.83 m) Color Change Cable (Part No.
123277, yellow color coded) from the Color Change
Module to the ProMix 3KS Fluid Station connector
(J2). See F
NOTE: If you are using two color change modules to
add component C change, connect a 5-pin electrical
cable from the first color change board to the second
color change board. See F
IG
. 3 and F
CAN Isolation Board Switch
Setting
Set switch S1 on CAN isolation board if color change
module and/or booth control are connected. See F
IG
. 11
and Table 2 on page 22.
F
IG
. 10. Power Supply Module Connections and AC Power Switch
AC Power
Switch
I/S Power
Ground Screw
Main Power
Access Port
TI14366a
TI14372a
VDC
VDC
Summary of Contents for ProMix 3KS
Page 27: ...Electrical 313881C 27...
Page 31: ...Electrical 313881C 31...