Fluid Supply
313881C
19
F
IG
. 7. Wall Mount Fluid Station, Sequential Dosing
TI14382a
Key:
MC
Component C Meter
DVC Component C Dose Valve
RVC Component C Sampling Valve
SVC Component C Shutoff Valve
CPV Component C Purge Valve
SM
Static Mixer
FI
Fluid Integrator
MC
CPV
DVC
SM
FI
SVC
RVC
3KS fluid inlet. Connect 6 ft (1.83 m) fluid supply line
from 2KS fluid manifold static mixer outlet to 1/4
npt(m) fitting.
Connect gun fluid supply line to 1/4 npt fluid outlet.
1
2
1
2
F
IG
. 8. Color Change Valves Air and Fluid Connections
Q
S
1
2
4
5
3
Connect solvent valve
air line here
Color Change Board and Solenoid Valves
Color
Change
Board
Solenoids
Color Change Valve Stack
Connect air lines to
valves here
Fluid Inlets
Fluid Inlets
Fluid Outlet
TI12824a
TI11668a
Connect 1/4 in. (6 mm) OD
solenoid air supply line
Communication ports
Summary of Contents for ProMix 3KS