Electrical
28
313881C
Connect Color Change Module
To install the color change module(s), see manual
312787.
Connect a 5-pin electrical cable from the labeled con-
nection port
(J2) on the 3KS fluid station control
board to the color change board. See F
If you are using two color change modules to add colors,
connect a 5-pin electrical cable from the first color
change board to the second color change board.
Set switches S3-S6 on the color change board(s) as
shown in Table 4 and F
. 16, depending on the number
of color change boards and color change modules being
used in your system.
For wiring between the color change board and the sole-
noids, see the color change module electrical sche-
matic, F
. 17.
Table 4: Color Change Board Switch Settings
Two Color Change Boards
Color Change Board 1
Color Change Board 2
Effect on System
S3
S6
S5
S4
S3
S6
S5
S4
Termination
Resistor
Board ID
Catalyst
On/Off
Color
On/Off
Termination
Resistor
Board ID
Component
C On/Off
Color
On/Off
OFF
ON
ON
ON
ON
OFF
OFF
ON
4 catalyst valves, 25 color
valves
OFF
ON
OFF
ON
ON
OFF
OFF
ON
0 catalyst valves, 25 color
valves
OFF
ON
ON
ON
ON
OFF
ON
ON
4 catalyst valves, 4 compo-
nent C valves, 25 color
valves
OFF
ON
OFF
ON
ON
OFF
ON
ON
4 component C valves, 25
color valves
One Color Change Board
ON
ON
ON
ON
NOT PRESENT
4 catalyst valves, 12 color
valves
ON
ON
ON
OFF
4 catalyst valves, 0 color
valves
ON
ON
OFF
ON
0 catalyst valves, 12 color
valves