INSTALLATION
Install the Interconnect Cables
1.
Connect the interconnect cable (406) between the
terminal block and voltage control. See Fig 6. Fasten
the cable in cable clamp to provide strain relief.
2.
Connect the voltage control ground cable (127) to
the strain relief/ground terminal.
3.
Connect the strain relief/ground terminal cable (X) to
a true earth ground.
4.
Connect the strain relief/ground terminal cable (W) to
the safety fence.
Install the Grounding Rod
Connect the grounding rod to the strain relief/ground ter-
minal. See Fig 6. Hook the grounding rod onto the fence
near the gate, as shown in Typical Installation.
Install the Fluid Supply Unit
1.
Place the fluid supply unit on the isolation stand. See
Fig 6.
2.
Connect the cable’s (405) c-clamp from the isolation
stand terminal block to a metal part of the fluid supply
unit.
Fig 6
Isolation
Stand
Voltage
Control
Strain Relief/
Ground Terminal
Connect cable
223–529 (406)
between
terminal
block & voltage control
Connect cable 223–548
(127) between
voltage
control base-plate & strain
relief ground terminal
Connect cable 223–547
(X) between
strain relief/
ground terminal &
true
earth ground (approx. 25 ft
(7.6 m) long)
Connect cable 223–539
(405) between
terminal
block & metal part of fluid
supply unit
Fluid Supply Unit
Grounding Grate
Terminal Block
Isolation Stand
Voltage Control Cable
Fluid Supply
Cable
Electrically
Conductive
Gun Air
Supply Hose
Grounding
Rod
Connect cable 223–685
(W) between
strain relief/
ground terminal & safety fence
(approx. 1 ft (0.3 m) long)
Cable Clamp
406
404
405
402
401