INSTALLATION
KEY TO TYPICAL INSTALLATION DRAWING
Ref Letter
Part No.
Description
Assembly Included With
See Page
A*
–
Grounded Main Air Supply Line
–
–
B
206–199
Gun Air Pressure Regulator
–
43
C*
235–070 (25’)
235–071 (36’)
235–072 (50’)
Gun Grounded Air Supply Hose
223–518 (25’)
See
223–519 (36’)
front
223–520 (50’)
cover
42
D
222–700
Water-base Electrostatic Spray Gun
223–518 (25’)
See
223–519 (36’)
front
223–520 (50’)
cover
37
E
–
Fluid Supply Air Pressure Regulator
SST Pressure Tanks
42
F*
185–918 (25’)
185–919 (36’)
185–920 (50’)
Gun Insulated Fluid Supply Hose
223–192 (25’)
223–193 (36’)
223–194 (50’)
40
G
223–640
Air Manifold Assembly
223–477
39
H*
–
Safety Fence Air Line Interlock
223–640 See page 39
–
J*
110–614
Safety Fence
–
42
K*
223–445 or 727–212
Isolation Stand
–
41 or 42
L*
223–639
Voltage Control
223–477
39
M
–
Fluid Supply Unit
–
42
N*
208–591
Fluid Supply Unit Non-conductive Air
Supply Hose
223–477
39
P*
185–972 & 185–971
Strain Relief/Ground Terminal
223–192 (25’)
223–193 (36’)
223–194 (50’)
40
Q*
–
Gun Air Hose Ground Wire
218–663 (25’)
218–664 (36’)
218–665 (50’)
42
R
223–446
Voltage Control Air Hose
223–477
39
S*
223–447
Safety Fence Interlock Air Hose
223–477
39
T
186–119
Safety Fence Warning Sign
223–477
39
U*
210–084
Grounding Rod
223–477
39
V*
110–790
U-Bolts and Plate
223–477
39
W*
223–685
Fence Ground Wire
223–477
39
X*
223–547
Main Ground Wire
223–477
39
Y*
223–548
Voltage Control Ground Wire
223–639
39
A safety fence (J), non-conductive hoses, isolation
stand (K), and voltage control (L) MUST be installed
to isolate the fluid in the fluid line (F), and fluid supply
unit (M) from ground and to prevent people from con-
tacting portions of the system that are charged to
high voltage. This helps reduce the risk of electric
shock, which could cause serious injury.
WARNING
The Typical Installation shown on page 4 is only a guide
for selecting and installing a water-base electrostatic air
spray system. It is not an actual system design. The par-
ticular type and size system for your operation must be
custom designed for your needs. For assistance in
designing a system, contact your Graco representative.
WARNING
Installing and servicing this equipment requires
access to parts which may cause electrostatic shock
or other serious bodily injury if work is not performed
properly. Do not install or service this equipment
unless you are trained and qualified.
Check and follow all local safety and fire codes,
NFPA 33, NEC 504 and 516, and OSHA standard
1910.107.
Warning Signs
Mount warning sign 186–118 (included with the spray
gun) in the spray area where it can easily be seen and
read by all operators. Mount warning sign 186–119
(included with the voltage control) on the safety fence
gate, as designated on the bottom of the sign. Additional
warning signs are available at no charge. See the spray
gun and voltage control PARTS LISTS or the
ACCESSORIES section to order them.