Repair
20
313937A
Repair
HydraCheck Kit Installation
Prepare Machine for Kit Installation
1.
Set Pump Mode switch to RETRACT.
2.
Relieve system pressure. See Pressure Relief Pro-
cedure on page 16.
3.
Remove shroud screws.
4.
Remove the shroud (107).
Install HydraCheck Shock
5.
Install shock absorber through the opening in the
pump sub-assembly with the groove for the snap
ring on the back of the pump assembly. The shock
absorber can be inserted through the front or the
back of the pump sub-assembly.
6.
Install shock snap ring (included with shock, not
shown) onto the shock absorber in the groove far-
thest from the pump sub-assembly.
7.
Install set screw and torque to 85 in-lb (9.6 N•m).
F
IG
. 6: HydraCheck Installation - Fixed Ratio Base
100d
100b
420
103
104
ti12436a
See Kits on page 29 for kit numbers.
Be sure that system pressure is relieved and dis-
abled before proceeding.
Summary of Contents for Pneumatic PR70
Page 32: ...Dimensions 32 313937A ...