background image

Operation

310864C

5

Operation

1.

To raise or lower the drain bowl (G), loosen knob (L), 
adjust drain tube (H) to desired height, and retighten 
knob (L).

2.

Ensure that the ball valve (O) on the drain tube (H) 
is open (red handle is down), when collecting used 
oil.

3.

When the tank is full or nearly full, as indicated on 
oil level gauge (P), it is time to empty the tank.

Emptying

1.

Close ball valve (O) on the drain tube (red handle is 
horizontal).

2.

Remove plug cap from the end of discharge hose 
(R) and place end of hose in a suitable used-oil con-
tainer.

3.

Open ball valve (S) at the discharge hose connec-
tion.

4.

Connect 8 psi, (55 kPa, .5 bar) compressed air to 
tank air valve (T).

5.

When the tank is empty, close ball valve (S) and 
open ball valve (O).

6.

The tank is ready for continued use.

Service

See page 6 for service/repair kits that are available for 
your Oil Ace pressurized oil drain system. Follow 
assembly instructions on page 4 and part locations indi-
cated on page 6 to replace parts. To simplify reassem-
bly, make note of the position and order of worn parts 
when removing them, and assemble new parts in the 
same fashion.

CAUTION

Never fill the tank beyond the maximum level indi-
cated on the oil level gauge (P) located on the side of 
the tank. Monitor the oil level regularly to ensure you 
do not overfill the tank.

CAUTION

To ensure pressurization, adjust the drain tube (H) to 
it’s fully extended position before emptying the tank. 

If you should inadvertently attempt to empty the 
tank before you fully extend the drain tube, the tank 
will not pressurize and therefore will not empty.

Summary of Contents for Oil Ace A Series

Page 1: ...01 310864C Instructions Parts List 24 Gallon 90 Liter Oil Ace Pressurized oil drain for collection of used lubricants and anti freeze Model 119577 Series A 8 psi 55 kPa 5 bar Maximum Working Pressure...

Page 2: ...us situation which if not avoided may result in property damage or destruction of equipment Additional helpful information WARNING FIRE AND EXPLOSION HAZARD When flammable fluids are present in the wo...

Page 3: ...dify equipment For professional use only Use equipment only for its intended purpose Call your Graco distributor for information Route hoses and cables away from traffic areas sharp edges moving parts...

Page 4: ...Insert the drain tube H through threaded opening on top of tank and hand tighten collar K on threads 6 Connect drain bowl G to drain tube H and tighten screw J to secure 7 Loosen knob L and raise or...

Page 5: ...e ball valve S and open ball valve O 6 The tank is ready for continued use Service See page 6 for service repair kits that are available for your Oil Ace pressurized oil drain system Follow assembly i...

Page 6: ...ck washers 2 crown nuts 2 1 3 119578 Air valve kit Includes Y fitting safety valve tank valve 1 4 119580 Gauge tube kit Includes gauge tube with incre mentally marked label elbows 2 tube fittings 2 1...

Page 7: ...cm Width 16 in 40 6 cm Height with drain bowl at lowest adjustment 56 5 in 143 5 cm with drain bowl at highest adjustment 80 in 203 cm Funnel diameter 24 in 61 cm Dry weight 74 lb 33 6 kg Wetted part...

Page 8: ...manship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR I...