Registering the PAC

312417F

5

Registering the PAC

1.

Press and hold NET ID button (c) (F

IG

. 2) to incre-

ment NET ID to match desired Network ID.

2.

Press and hold TRANS ID button (d) (F

IG

. 2) to 

increment TRANS ID to match desired Transceiver 
ID.

3.

Once the correct NET ID and TRANS ID are flash-

ing, to register the PAC with Matrix

 PC Software, 

press and hold both buttons (c) and (d) for a few 
seconds until you notice the display:

momentarily go black, 

then flicker, 

and then the numbers reappear steady. 

Mode Configuration

1.

Press and hold MODE button (e) (F

IG

. 2) to select 

Matrix or Override mode.

In the MATRIX (preferred) (g) (F

IG

. 2) mode, the 

pump will not operate unless it receives an 
authorization code from Matrix software. Unau-
thorized dispenses are not allowed in this mode.

The OVERRIDE mode (f) (F

IG

. 2), turns on air to 

the pump so the pump can be used without 
authorization through Matrix. VALVE ON LED 
(h) will indicate the solenoid valve is acti-
vated/deactivated.

F

IG

. 2

The flicker is a signal that the PAC has suc-
cessfully been registered with Matrix.

Numbers will flash until PAC unit is successfully 
registered with Matrix PC software.

ti11964a

(c)

(d)

(e)

(f)

(g)

(h)

The LED next to selected mode will illuminate to 
indicate which mode, OVERRIDE (f) or MATRIX (g) 
is selected.

Summary of Contents for Matrix PAC 247436

Page 1: ...Pa 1 7 bar Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ti11959a Pump Air Control contains an RF devise with the following approvals FCC ID T...

Page 2: ...plug or unplug power cords or turn lights on or off when flammable fumes are present Ground all equipment in the work area Use only grounded hoses If there is static sparking or you feel a shock stop...

Page 3: ...mpletely remove cable 5 Loosen screw c on the back of the mini DIN sole noid connection and disconnect solenoid 6 Remove screw e from front cover f on mini DIN solenoid connection 7 Inside mini DIN so...

Page 4: ...2 and green wire to GROUND 12 Replace cover f and screw e on mini DIN sole noid connection 13 Reconnect mini DIN solenoid connection to sole noid 14 Tighten screw c on back of mini DIN solenoid con n...

Page 5: ...d MODE button e FIG 2 to select Matrix or Override mode In the MATRIX preferred g FIG 2 mode the pump will not operate unless it receives an authorization code from Matrix software Unau thorized dispe...

Page 6: ...1 4 turn 3 Before you can resume normal PAC communication with Matrix you must reset the Manual Override Switch screw A to the normal operation position To to this insert small flat screwdriver in the...

Page 7: ...urrent due to static build up or in the event of a short circuit Connect power cord to a 3 wire grounded plug according to your local electrical code The green ground wire must be attached to the gree...

Page 8: ...4 No communication with internal RF module Replace circuit board Problem Cause Solution Flashing Seven Segment Display with NET ID and TRANS ID Unit is not registered with Matrix PC software Hold bot...

Page 9: ...4 Leave the drain valve open until you are ready to pressurize the system Solenoid 2 Replacement For the following instructions refer to FIG 5 and parts pages 10 and 10 1 Unplug power cord from outlet...

Page 10: ...Parts 10 312417F Parts 15 1 5 19 4 8 12 11 13 14 10 9 18 7 3 6 17 2 ti12325a Model 247436 Torque to 20 in lbs 2 N m 1 Torque to 25 in lbs 3 N m 2 Apply pipe sealant 3 3 2 1 5a...

Page 11: ...EL identification 1 F N Part No Description Qty Operating Pressure Range 23 145 PSI 1 7 10 bar Maximum Air Flow 93 SCFM 2 6m3 min Air Supply to PAC 3 8 NPT Female Air Outlet to Pump 3 8 NPT Female Pow...

Page 12: ...n of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRAN...

Reviews: