Setup
3A2960A
15
•
Pump OFF time is shown in HH:MM (hours:minutes)
or MM:SS if the time remaining is less than an hour.
Timer Mode: Pump ON
The display indicates the amount of time remaining in
the pump cycle, counting down the Pump ON time value
(see Time Control (on:ti) ON Setup, page 12).
•
The Pump output is enabled.
•
Pump ON time is shown in MM:SS (minutes:sec-
onds)
Timer Mode: Pump OFF
The display indicates the amount of time remaining in
the pump OFF cycle, counting down the Pump OFF time
value (see Programming OFF Time Duration, page 13).
•
The Time OFF LED illuminates and the pump output
is disabled during the Pump OFF time.
•
Pump OFF time is shown in HH:MM (hours:minutes)
or MM:SS if the time remaining is less than an hour.
Alarm Operation
When an alarm situation occurs:
•
pump operation is immediately
disabled,
•
the front panel Alarm LED illuminates,
•
an error code displays
•
an audible alarm sounds
•
the alarm output contact activates
Press the Reset button once to clear
buzzer; press and hold for 3 seconds
to clear warning and switch controller
to OFF MODE.
Alarm Types and Messages
Alarm Type
Error Code
Low Level
Er LL
Cycle
Er CY
Pressure
Er Pr
System Fault
Er SY