Setup 

14

3A2960A

Programming the Low Level (LL:dF) Setting

LL:dF displays. This is the basic configuration and 
requires one activation. 

1.

Use the UP or DOWN ARROW to 
cycle through until LL:93 displays. 
This will set the controller up to 
use the G3 low level algorithm.

2.

Press the ENTER button to lock in the selection. 

NOTE

: When the user exits SETUP MODE, the pro-

gramming information is saved and the OFF TIME infor-
mation is saved. The controller goes to the beginning of 
a PUMP OFF Cycle.

Operation

Run Mode

The controller is in Run Mode Providing the following cir-
cumstances are not present:

The controller is not in SETUP MODE

An Alarm is not active

Pressure Mode: Pump ON

The display indicates the amount of backup time 
remaining (see Pressure Mode (on:Pr) ON setup, page 
12). 

The Pressure ON LED illuminates and the pump 
output is enabled as long as the system is in the 
Pump ON state.

If the pressure switch input is activated before the 
Backup Pump On Time expires, the system 
switches to a Pump OFF state. 

If the pressure switch is NOT activated before the 
Backup Pump On Time expires the system faults, 
goes to the Pump OFF state and pauses until the 
alarm is cleared.

Pump ON time is shown in MM:SS (minutes:sec-
onds)

Pressure Mode: Pump OFF

The display indicates the amount of time remaining in 
the pump OFF cycle, counting down the Pump OFF time 
value (see Programming OFF Time Duration, page 13).

The pump output is disabled during the Pump OFF 
time.

The Time OFF LED is illuminated as long as the 
system is in the Pump OFF state.

Pump OFF time is shown in HH:MM (hours:minutes) 
or MM:SS if the time remaining is less than an hour.

Cycle Mode: Pump ON

The display alternates between the number of cycles 
remaining and indicates the amount of time remaining in 
the pump cycle, counting down the Backup Pump ON 
time value (see Cycle Mode (on:CY) ON Setup, page 
12).

The Cycle ON LED illuminates and the pump output 
is enabled as long as the system is in the Pump ON 
state.

If the Input Cycle Switch is activated the amount of 
times equal to the Cycle Definition variable before 
the Backup Pump On Time expires, the system 
switches to a Pump OFF state. 

If the cycle switch is NOT activated the number of 
times equal to the cycle definition variable before 
the Backup Pump On Time expires the system 
faults, goes to the Pump OFF state and pauses until 
the Alarm is cleared.

Pump ON time is shown in MM:SS (minutes:sec-
onds)

Cycle Mode: Pump OFF

The display indicates the amount of time remaining in 
the pump OFF cycle, counting down the Pump OFF time 
value (see Programming OFF Time Duration, page 13).

The pump output is disabled during the Pump OFF 
time.

The Time OFF LED illuminates as long as the sys-
tem is in the Pump OFF state.

Summary of Contents for GLC 2200

Page 1: ...For controlling and monitoring an automated lubrication system Not approved for use in explosive atmospheres or hazardous locations Model 24N468 Important Safety Instructions Read all warnings and in...

Page 2: ...the maximum working Pressure or temperature rating of the lowest rated system com ponent See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted p...

Page 3: ...nd an audible alarm also sounds RIGHT Direction Arrow MANUAL RUN ENTER G In SETUP MODE saves entry moves cursor in display one field to the right or to the next setup step In RUN MODE activates the pu...

Page 4: ...B Filter Regulator Lubricator Assembly B1 Filter B2 Regulator B3 Lubricator C Air Solenoid Valve D Pump Module E Ignition Switch F High Pressure Lubricant Supply Lines G Injector Banks H Lubrication...

Page 5: ...les FIG 3 a Use two screws not provided to secure junction box to mounting surface AUTOMATIC SYSTEM ACTIVATION HAZARD Unexpected activation of the system could result in seri ous injury including skin...

Page 6: ...to determine the Required System Configuration Sensor Configuration and Wiring Diagram to use to setup your system Table 4 shows additional optional setup configurations Table 1 System Configurations...

Page 7: ...Installation 3A2960A 7 System Configuration FIG 4 GLC 2200 Low Level Switch Pump Reservoir Injector System Pressure Switch Injectors Lubrication Points Vent Line Pump On Off External Alarm...

Page 8: ...Installation 8 3A2960A FIG 5 GLC 2200 Low Level Switch Pump Reservoir Master Divider Valve Secondary Divider Valves Cycle Switch Series Progressive System Pump On Off External Alarm...

Page 9: ...Installation 3A2960A 9 FIG 6 GLC 2200 External Alarm Low Level Switch Pump Reservoir Dual Line System Cycle Switch Bi flo Valves Lubrication Points Vent Line Pump On Off Reverser...

Page 10: ...Installation 10 3A2960A Sensor Wiring Configurations DRY CONTACT SWITCH SOURCE SWITCH 2 or 3 Wire Type FIG 7 4 9 FIG 8 4 9 VDC...

Page 11: ...odes of GLC2200 Operation Wiring Key Connector Identification Label FIG 9 1 2 3 4 5 6 7 8 9 10 M 9A Fuse Pin Description 1 Pump 2 Alarm 3 Low Level 4 Pressure Cycle Switch 5 Voltage Input 6 Pump 7 Ala...

Page 12: ...ock in the selec tion 3 Pressure control is an ON OFF selection only Not additional pro gramming is required Cycle Mode on CY ON Setup 1 Use the UP or DOWN ARROW to cycle through the on Pr on CY or on...

Page 13: ...S field value is 59 The controller automatically switches to the OFF TIME SETUP MODE Programming OFF TIME Duration After setting the parameters for either Pressure P Cycle C or Time T ON Modes the OFF...

Page 14: ...dicates the amount of time remaining in the pump OFF cycle counting down the Pump OFF time value see Programming OFF Time Duration page 13 The pump output is disabled during the Pump OFF time The Time...

Page 15: ...time value see Programming OFF Time Duration page 13 The Time OFF LED illuminates and the pump output is disabled during the Pump OFF time Pump OFF time is shown in HH MM hours minutes or MM SS if the...

Page 16: ...pen level switch closes upon low level Outputs Pump control Pump Control Voltage Power Source Voltage Power Source Max Switching Voltage 30 VDC Max Switching Current 9A DC Alarm normally open Voltage...

Page 17: ...Dimensions 3A2960A 17 Dimensions Mounting Hole Layout 2 75 in 69 85 mm 5 5 in 139 7 mm 1 23 in 31 24 mm 1 63 in 41 4 mm 4 95 in 125 8 mm...

Page 18: ...rtation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor an...

Reviews: