background image

Instructions

GLC 2200 
Lubrication Controller

3A2960A

For controlling and monitoring an automated lubrication system. 

Not approved for use in explosive atmospheres or hazardous locations.

Model: 24N468

Important Safety Instructions
Read all warnings and instructions in this 
manual. Save these instructions.

EN

Summary of Contents for GLC 2200

Page 1: ...For controlling and monitoring an automated lubrication system Not approved for use in explosive atmospheres or hazardous locations Model 24N468 Important Safety Instructions Read all warnings and in...

Page 2: ...the maximum working Pressure or temperature rating of the lowest rated system com ponent See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted p...

Page 3: ...nd an audible alarm also sounds RIGHT Direction Arrow MANUAL RUN ENTER G In SETUP MODE saves entry moves cursor in display one field to the right or to the next setup step In RUN MODE activates the pu...

Page 4: ...B Filter Regulator Lubricator Assembly B1 Filter B2 Regulator B3 Lubricator C Air Solenoid Valve D Pump Module E Ignition Switch F High Pressure Lubricant Supply Lines G Injector Banks H Lubrication...

Page 5: ...les FIG 3 a Use two screws not provided to secure junction box to mounting surface AUTOMATIC SYSTEM ACTIVATION HAZARD Unexpected activation of the system could result in seri ous injury including skin...

Page 6: ...to determine the Required System Configuration Sensor Configuration and Wiring Diagram to use to setup your system Table 4 shows additional optional setup configurations Table 1 System Configurations...

Page 7: ...Installation 3A2960A 7 System Configuration FIG 4 GLC 2200 Low Level Switch Pump Reservoir Injector System Pressure Switch Injectors Lubrication Points Vent Line Pump On Off External Alarm...

Page 8: ...Installation 8 3A2960A FIG 5 GLC 2200 Low Level Switch Pump Reservoir Master Divider Valve Secondary Divider Valves Cycle Switch Series Progressive System Pump On Off External Alarm...

Page 9: ...Installation 3A2960A 9 FIG 6 GLC 2200 External Alarm Low Level Switch Pump Reservoir Dual Line System Cycle Switch Bi flo Valves Lubrication Points Vent Line Pump On Off Reverser...

Page 10: ...Installation 10 3A2960A Sensor Wiring Configurations DRY CONTACT SWITCH SOURCE SWITCH 2 or 3 Wire Type FIG 7 4 9 FIG 8 4 9 VDC...

Page 11: ...odes of GLC2200 Operation Wiring Key Connector Identification Label FIG 9 1 2 3 4 5 6 7 8 9 10 M 9A Fuse Pin Description 1 Pump 2 Alarm 3 Low Level 4 Pressure Cycle Switch 5 Voltage Input 6 Pump 7 Ala...

Page 12: ...ock in the selec tion 3 Pressure control is an ON OFF selection only Not additional pro gramming is required Cycle Mode on CY ON Setup 1 Use the UP or DOWN ARROW to cycle through the on Pr on CY or on...

Page 13: ...S field value is 59 The controller automatically switches to the OFF TIME SETUP MODE Programming OFF TIME Duration After setting the parameters for either Pressure P Cycle C or Time T ON Modes the OFF...

Page 14: ...dicates the amount of time remaining in the pump OFF cycle counting down the Pump OFF time value see Programming OFF Time Duration page 13 The pump output is disabled during the Pump OFF time The Time...

Page 15: ...time value see Programming OFF Time Duration page 13 The Time OFF LED illuminates and the pump output is disabled during the Pump OFF time Pump OFF time is shown in HH MM hours minutes or MM SS if the...

Page 16: ...pen level switch closes upon low level Outputs Pump control Pump Control Voltage Power Source Voltage Power Source Max Switching Voltage 30 VDC Max Switching Current 9A DC Alarm normally open Voltage...

Page 17: ...Dimensions 3A2960A 17 Dimensions Mounting Hole Layout 2 75 in 69 85 mm 5 5 in 139 7 mm 1 23 in 31 24 mm 1 63 in 41 4 mm 4 95 in 125 8 mm...

Page 18: ...rtation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor an...

Reviews: