Max Model Setup
38
332305G
Delaying the prelube function may be desired if other
critical functions or systems of your machine or vehicle
are also coming on line during power up.
1.
Prelube Delay is set in
MM:SS (minutes and sec-
onds). To set the time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 5 until the desired number
appears in the first MM (minutes) field.
The maximum length of time Prelube Delay can be
set to is 59:59 (59 minutes:59 seconds).
2.
Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
3.
Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4.
Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
5.
Repeat steps 1 - 4 to set the SS (seconds) fields.
6.
After pressing the ENTER button to set
the last SS field the G3 automatically
switches to the RUN MODE.
DMS
™
Models Only
Downloading Data
1.
Plug the USB flash drive into the USB port.
NOTE:
The G3 pump stops pumping as soon as the
USB flash drive is plugged into it.
2.
The system automatically begins downloading data
to the USB drive.
3.
“data” is displayed while the system
is downloading files.
4.
When download is finished, “done” is
displayed.
5.
G3 pump restarts cycle in the OFF mode.
6.
Remove the USB flash drive.
Storing Pump Program Settings
to the Flash Drive
The pump program settings file is named:
GRACO/G3Config/g3config.bin. This file cannot be
modified. Modification of the file or file name may cause
it to be unusable.
1.
Plug the USB flash drive into the USB port.
NOTE:
The G3 pump stops pumping as soon as the
USB flash drive is plugged into it.
2.
The system automatically begins downloading data
to the USB drive.
3.
“data” is displayed while the system
is downloading files.
4.
When download is finished, “done” is
displayed.
5.
G3 pump restarts cycle in the OFF mode.
6.
After the download is com-
plete, press and hold the UP
and DOWN ARROW button
for 3 seconds to store the cur-
rent setup to the USB flash
drive.
7.
“data” is displayed while the unit is
downloading and storing the configu-
ration on the USB drive.
8.
When configuration is stored, “done”
is displayed.
9.
G3 pump restarts cycle in the OFF mode.
10. Remove the USB flash drive.