Max Model Setup
34
332305G
the display, press the ENTER button to save selec-
tion.
If the sensor inputs are available and none are used in
the ON Mode, the definition of the entered time is ON
TIME.
Examples:
Model G3-G-24MX-2LFL00-1DMVA2R3 has 4 sensors,
so C/P1, C/P2, and C/P3 and Machine Count can all be
programmed.
Model G3-G-24MX-2LFL00-10CV00R0 has 1 sensor,
only C/P1 is available for programming.
Backup Time
In both Cycle and Pressure Modes, a maximum run
Time (Backup Time) for the lubrication period must be
set up. If this Time expires before the lubrication is com-
pleted an alarm/warning is triggered and the pump
stops.
To determine the Backup Time, Graco recommends the
user verify the length of time it takes to complete a typi-
cal cycle and double that value (to a maximum of 30
minutes).
Backup Time is setup after Cycle or Pressure Sensor
Setup is complete.
NOTE:
•
The LED next to the clock in the ON field lights, indi-
cating the Backup Time is being programmed.
•
BACKUP (ON) Time is set as minutes and seconds
(MM:SS) only.
•
The small flashing LED under the MM indicates you
are setting minutes.
•
The first field (left side of display) blinks indicating
the device is ready for you to begin programming.
Programming Backup Time
NOTE:
When programming a time of less than 10 min-
utes
you
must
program the leading zero in the first num-
ber field and press the ENTER button to save the zero
selection.
1.
To set the ON Time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 5 until the desired number
appears in the first MM (min-
utes) field.
2.
Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
3.
Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4.
Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
5.
Repeat steps 1 - 4 to set the SS (seconds) fields.
6.
After pressing the ENTER button to set
the last SS field, all the programmed ON
Time information is saved.
The G3 automatically switches to the OFF Time
SETUP MODE.
ON Time
•
The LED next to the clock in the ON
field lights, indicating you are setting
the ON Time parameters.
•
ON Time is set in Minutes and Seconds (MM: SS).
•
An LED flashes under
either MM when pro-
gramming minutes
OR
SS when pro-
gramming seconds.
OR