
Max Model Setup
32
332305G
3.
Use the UP and DOWN ARROW
buttons to move up and down
through the numbers 0-9 until the
second digit of the date is dis-
played in the field.
4.
Press the ENTER button to set the
date.
The time displays indicating the G3 is now ready to
program the time.
Enter the Time:
•
The time displays in 24-Hour format. i.e., 2:45 PM
displays as 14:45.
•
The clock is set in Hours and Minutes (HH:MM).
•
The LED under the
HH lights when set-
ting hours and the
LED under the MM
lights when setting
minutes.
•
The first programmable number of the HH (hour)
filed blinks, indicating the device is ready to program
the first digit of the hour.
•
When programming a time of less then 12 hours,
you must program a leading zero in the first number
field and press the ENTER button to save the zero.
1.
Use the UP and DOWN ARROW
buttons to move up and down
through the numbers 0-2 until the
desired number appears in the first
hour (HH) field.
2.
Press the ENTER button to set the
number.
3.
Use the UP and DOWN ARROW buttons to move
up and down through the numbers 0-9 until the
desired number for the second HH number field
appears.
4.
Press the ENTER button to set the
number.
5.
The next number field to the right blinks and the
LED under the MM lights indicating the G3 is ready
to program the minutes fields.
6.
Repeat steps 1-4 to set the minutes (MM) fields.
7.
After pressing the ENTER button to
set the time, the programmed Time
information is saved.
Programming ON Duration
•
OFF, C1 (C2, C3) or
P1 (P2, P3) displays,
identifying the func-
tion you are program-
ming.
•
Selection of OFF, C1 (C2, C3) or P1 (P2, P3) desig-
nates the way pump run time is controlled:
•
C1, C2, C3 - Completing a specific number of
cycles measured by an external prox/cycle
switch
•
P1, P2, P3 - Reaching a specific pressure
threshold measured by an external pressure
switch -
OR
,
•
OFF - A specific duration of time elapses.
•
The LED next to C/P1 lights, indicat-
ing which sensor of the pump control
you are programming using either a
specific number of cycles or by mon-
itoring a pressure switch.
•
C / P2 and C / P3 controls functions to the second
and third sensors (when sensors are used).
•
Only sensor inputs that are available on the unit can
be programmed.
NOTE:
Field cannot be left blank. If C / P2 and C /
P3 are not used, OFF must be entered instead.
Cycle (C1, C2, C3) Setup
Cycle controls the number of lube cycles (as monitored
by an external cycle monitor) completed before the
pump rests.
NOTE:
•
You must program at least
one
cycle. Zero is not an
available option.
1.
Use UP or DOWN arrow but-
ton to toggle display between
OFF / C1 / P1 on the display.
or