Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.

NOTE:

NOTE:

NOTE: For complete Technical Specification
information, see Driver Operation manual.

Power

Power

Power Supply

Supply

Supply Requirements

Requirements

Requirements

Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
local codes and regulations.

See the table below for power supply requirements.
The driver requires a dedicated circuit protected with
a circuit breaker.

Model

Model

Model

Voltage

Voltage

Voltage

Phase

Phase

Phase

Hz

Hz

Hz

kVA

kVA

kVA

24X901

200–240
Vac

1

50/60

2.5

NOTE:

NOTE:

NOTE: The protective earthing ground conductor
must be equal to the phase conductions..

Hazardous

Hazardous

Hazardous Area

Area

Area Cabling

Cabling

Cabling and

and

and Conduit

Conduit

Conduit

Requirements

Requirements

Requirements

Explosion

Explosion

Explosion Proof

Proof

Proof

All electrical wiring in the hazardous area must be
encased in Class I, Division I, Group D approved
explosion-proof conduit. Follow all National, State,
and Local electric codes.

A conduit seal is required within 18 in. (457
mm) of the driver for the US and Canada. See

Connect Power, page 10

.

All cables must be rated 70°C minimum.

Flame

Flame

Flame Proof

Proof

Proof (ATEX)

(ATEX)

(ATEX)

Use appropriate conduit, connectors, and cable
glands rated for ATEX II 2 G. Follow all local codes
and regulations.

All cable glands and cables must be rated 70°C
minimum.

8

3A3165H

Summary of Contents for Ex35

Page 1: ...protective protective coatings coatings coatings using using using e e e Xtreme Xtreme Xtreme Sprayers Sprayers Sprayers For For For professional professional professional use use use only only only...

Page 2: ...ver Model 3 Related Manuals 3 Warnings 4 Component Identification 7 Installation 8 Power Supply Requirements 8 Hazardous Area Cabling and Conduit Requirements 8 Grounding 9 Connect Power 10 General Re...

Page 3: ...Ex d IIA T4 Gb 5 C Ta 50 CFM20CA0054X List List List of of of Standards Standards Standards IEC 60079 0 IEC 60079 1 EN 60079 0 EN 60079 1 ANSI ISA 60079 0 ANSI UL 60079 1 FM 3600 FM 3615 FM 3810 CSA...

Page 4: ...less they are anti static or conductive Stop Stop Stop operation operation operation immediately immediately immediately if static sparking occurs or you feel a shock Do not use equipment until you id...

Page 5: ...e guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure...

Page 6: ...onent See Technical Technical Technical Specifications Specifications Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Tech...

Page 7: ...on Description Description A Driver C Lift Ring G Oil Drain Plug H Driver Output Shaft K Oil Sight Glass L Status Indicator Light LED N Pressure Control Knob P Oil Fill Cap vented S Power Switch Lock...

Page 8: ...rcuit breaker Model Model Model Voltage Voltage Voltage Phase Phase Phase Hz Hz Hz kVA kVA kVA 24X901 200 240 Vac 1 50 60 2 5 NOTE NOTE NOTE The protective earthing ground conductor must be equal to t...

Page 9: ...ire for the electric current Driver Driver Driver The driver is grounded through the power cord Driver Driver Driver optional optional optional secondary secondary secondary Pump Ground Wire Two groun...

Page 10: ...eal D is required within 18 in 457 mm of the driver for the US and Canada 4 15 in lb maximum terminal bushings 2 To install wiring locate the electrical junction box Y Remove four screws J and junctio...

Page 11: ...ipment power and shut off power at the main circuit breaker before repairing Wear appropriate protective equipment when in work area Wait five minutes before servicing Make sure wires are not pinched...

Page 12: ...on Graco reserves the right to make changes at any time without notice Original Instructions This manual contains English MM 3A3165 3A3165 3A3165 Graco Graco Graco Headquarters Headquarters Headquarte...