ADM Screen Overview
3A6165J
51
Setup Screen 2
This screen allows the user to set a Gel Timer and Pres
-
sure Preset.
Gel Timer:
When enabled, the gel timer prevents mate
-
rial from curing in the mixer. The user can select a
sequence to run, as well as the amount of idle time the
machine can wait between dispenses. If the system
does not dispense again before the set time runs out,
the gel timer will dispense the preset sequence.
Enable:
Check this box to enable the gel timer.
Idle Period:
This is the amount of time the unit will
remain idle before beginning to dispense.
Alarm:
This is the amount of time the EFR will wait after
the idle period has been reached. This allows time for
the robot to move into the purge location.
Repeat Until:
The selected sequence will be repeated
until the specified amount of material has been purged.
Pressure Preset:
The pressure preset allows the user to
select the sequence that will run when the prime icon
is pressed on the home screen. The user can
either select the Active Sequence, which is shown on
the home screen, or one of the other sequences listed in
the drop down menu for the pressure preset. Running
the pressure preset allows the EFR to learn the running
pressure and prime the system.
Repeat Until:
The selected sequence will be repeated
until the specified amount of material is reached during
priming.
Setup Screen 3
This screen allows the user to monitor inlet and outlet
pressures of the EFR during a dispense. The user can
specify a minimum and maximum allowable value for A
and B for both inlet and outlet pressures. The user can
also specify the level of alerts for each individual pres
-
sure limit. The alert options include Disabled, Deviation,
and Alarm.
Disabled:
No pressure monitoring will occur.
Deviation:
The user will be notified if the pressure goes
below the minimum or above the maximum, but further
dispensing will be allowed to occur.
Alarm:
If the pressure goes below the minimum or
above the maximum, the current dispense will stop and
further dispensing will not be allowed until the alarm is
acknowledged.
NOTE:
Inlet pressure monitoring is only available on
systems with the Pressure Transducer Kit (25B128)
installed. Setup screen 3 will only display outlet monitor
-
ing if the kit is not installed.