Troubleshooting
3A6165J
35
P7DB
Pressure Imbalance
High B
Dispense line is clogged
First try purging fresh material
through the system. Then relieve
pressure and check for cured
material or obstructions in the
dispense valve.
Orifice restrictions sized incorrectly
Adjust orifice restrictions to balance
pressure of A and B materials
Out of material
Verify A material supply
Pressure imbalance is defined too
low
Increase pressure imbalance
amount from the Setup screen of the
Advanced Display Module (ADM)
T4NX
High Temperature
Motor
Cooling fans not working properly
Ensure cooling fans are clear of
obstructions and operating properly
V1NX
Low Voltage Motor
AC voltage is too low
Check wire connections and verify
line voltage is within specification
V4NX
High Voltage Motor
AC voltage is too high
Verify line voltage is within
specification
WBNX
Encoder Error Motor Encoder not plugged in
Ensure encoder connector is fully
plugged into the circuit board inside
the driver
Faulty encoder
Replace encoder
WMNX
Controller Fault
Motor
Faulty circuit board
Replace motor control circuit board
WVCX
Voltex Dynamic Mix
Valve Motor Fault
Over Torque
Cycle Power. Increase Ramp up
time. Cycle power to unit.
Clean mixer. Cycle power to unit.
No power to motor
Make sure that motor has power.
Check power supply if need cycle
power.
W5NX
Encoder Calibration
Motor
Encoder not calibrated
Calibrate the Encoder from the
maintenance screen of the
Advanced Display Module (ADM)
Error Code
Code Description
Cause
Solution