Troubleshooting
3A6917A
19
5
Deviation
Low Temperature
Warm equipment.
6
Alarm
Motor Temperature Fault
Motor is running too hot. Allow unit to cool.
•
Reduce pressure.
•
Move the unit to a cooler location.
7
Alarm
Board Temperature Fault
The control board is running too hot. Allow the unit to cool.
•
Reduce pressure.
•
Move the unit to a cooler location.
8
Alarm
Encoder Calibration Error
•
Cycle power and check status indicator (L) to see if the error is still active.
•
Follow the calibration procedure listed in the e-Xtreme Driver
Operation/Repair manual to calibrate the encoder (this code will blink if
calibration is in progress).
•
Contact your Graco distributor or Tech Service for more information.
9
Alarm
Encoder Error
•
Cycle power and check the status indicator (L) to see if the error is still active.
•
Verify that the internal connections are intact.
•
Contact your Graco distributor or Tech Service for more information.
10
Alarm
Software Versions Do Not Match
Obtain software update token. See Accessories section for token part number.
See the Driver Operation/Repair manual for token installation information.
11
Alarm
Circuit Board Communication Failure
Cycle power and check status indicator (L) to see if the error is still active.
Contact your Graco distributor or Tech Service for more information.
12
Alarm
Internal Circuit Board Hardware Failure
Cycle power and check status indicator (L) to see if the error is still active.
Contact your Graco distributor or Tech Service for more information.
13, 14
Alarm
Internal Software Error
Cycle power and check status indicator (L) to see if the error is still active.
Contact your Graco distributor or Tech Service for more information.
Slow Blink
Deviation
See
, page 18.
Blink Code
Error Type