![background image](http://html.mh-extra.com/html/graco/e-xtreme-z60/e-xtreme-z60_instructions-manual_2251257008.webp)
Setup
8
3A6917A
Install Vented Oil Cap Before
Using Equipment
The driver gear box is shipped from the factory pre-filled
with oil. The temporary unvented cap (PX) prevents oil
leaks during shipment. This temporary cap must be
replaced with the vented oil cap (P) before use.
Flush Before Using Equipment
The pump fluid section was tested with lightweight oil,
which is left in the fluid passages to protect parts. To
avoid contaminating your fluid with oil, flush the
equipment with a compatible solvent before using the
equipment.
See
Setup
1.
Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
2.
Turn power switch (E) OFF. Connect unit to power
source.
3.
Check packing nut (D). See your Xtreme lower
pump manual for packing nut torque. Fill with Throat
Seal Liquid (TSL
™
).
4.
Attach electrically conductive fluid hose to the pump
lower outlet via the outlet check valve and tighten.
5.
Attach the hose to the gun and tighten.
To avoid tipping over, make sure the cart is on a flat
and level surface. Failure to do so could result in
injury, such as crushing.
PX
P
ti36317a
H
NOTICE
Attaching the hose directly to the lower pump can
result in damage to the sprayer during cavitation, or
when the sprayer runs out of material. Use an outlet
check valve between the lower pump and hose to
avoid damage.
NOTICE
The minimum hose size allowable is 3/8 in. ID x 50 ft
(10 mm x 15 m). Smaller hoses can cause high
pressure spikes and result in damage to the sprayer.
WLD
OFF
E
WLD
76/