Repair
48
3A8217A
5. Disconnect Driver (AB):
a. Attach a secure hoist to the driver lift ring.
Loosen nut (125) below crossbar.
b. Use wrench to hold lift ring adapter (127) in
place and loosen threaded rod (126) above
crossbar with another wrench. See F
Install Driver
D200s 6.5 in. Ram Supply Units
55 gallon platen:
1. Using a capable hoist, insert tie rods into the Dis
-
placement Pump (AC) and secure the Driver (AB) to
the Pump (AC).
a. See
Reconnect Displacement Pump
in your
Pump package manual.
b. Install threaded rod (126) through center hole in
the crossbar. Install lock washers (124) and nuts
(125) onto threaded rod (126), both above and
below crossbar. Use wrench to hold lift ring
adapter (127) and tighten threaded rod (106)
into lift ring adapter (127) using another wrench.
See F
c. Tighten nut (125) below crossbar to 25 ft-lb (34
N•m) maximum.
d. Tighten nut (125) above crossbar to lock Driver
(AB) in place.
F
IG
. 39
F
IG
. 40
F
IG
. 41: 55 Gallon Platen
HC
CG
AB
126
125
127
125
Lift Ring
To avoid serious injury when installing and removing
the Driver, make sure the Driver is supported at all
times.
F
IG
. 42
126
125
127
125
124