Maintenance
3A8217A
41
Platen Maintenance
1. Follow the steps to
2. Follow the
on page 36.
3. Refer to parts illustration on page 60 and remove
the platen check valve (449) as shown.
4. Clear air assist tube (AT) in Platen (AD).
5. Clean all parts of the platen check valve (449) and
replace if necessary.
6. Remove Bleed Stick (EF) from Platen (AD). Push
Bleed Stick through Bleed Relieve Ports (EG) to
remove material residue.
Remove and Reinstall Wipers
Remove Platen Wipers
1. Follow the
on page 36.
2. Turn the Power Junction Box Switch (AK) and the
Disconnect Switch (AZ) OFF.
3. To replace worn or damaged Wipers (EB), raise
Platen up out of drum. Remove drum from base.
Wipe fluid off of Platen.
4. Cut the Wiper(s) (EB) with knife and remove from
Platen. See F
F
IG
. 33
TI10613A
EB
55 Gallon Platen