Maintenance
Maintenance
Maintenance
Maintenance
Preventive
Preventive
Preventive Maintenance
Maintenance
Maintenance Schedule
Schedule
Schedule
The operating conditions of your particular system
determine how often maintenance is required.
Establish a preventive maintenance schedule by
recording when and what kind of maintenance is
needed, and then determine a regular schedule for
checking your system.
Change
Change
Change the
the
the Oil
Oil
Oil
NOTE:
NOTE:
NOTE: Change the oil after a break-in period of
200,000–300,000 cycles. After the break-in period,
change the oil once a year. Order two Part No.
16W645 ISO 220 silicone-free synthetic gear oil.
1.
Place a minimum 2 quart (1.9 liter) container
under the oil drain port. Remove the oil drain
plug (25). Allow all oil to drain from the motor.
2.
Reinstall the oil drain plug (25). Torque to 25–30
ft-lb (34–40 N•m).
3.
Open the fill cap (P) and add Graco Part No.
16W645 ISO 220 silicone-free synthetic gear
oil. Check the oil level in the sight glass (K). Fill
until the oil level is near the halfway point of the
sight glass. The oil capacity is approximately 1.5
quarts (1.4 liters). Do
Do
Do not
not
not overfill.
overfill.
overfill.
4.
Reinstall the fill cap.
Figure 14 Oil Drain Plug
Check
Check
Check the
the
the Oil
Oil
Oil Level
Level
Level
Check the oil level in the sight glass (K). The oil
level should be near the halfway point of the sight
glass when the unit is not running. If low, open the
fill cap (P) and add Graco Part No. 16W645 ISO
220 silicone-free synthetic gear oil as required. Do
Do
Do
not
not
not overfill.
overfill.
overfill.
Figure 15 Sightglass and Oil Fill Cap
16
3A2526L