Installation
Installation
Installation
Installation
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.
NOTE:
NOTE:
NOTE: To install an advanced motor, also see
Intrinsically Safe Installation Requirements for
Advanced Motors, page 12
.
Check
Check
Check the
the
the Oil
Oil
Oil Level
Level
Level Before
Before
Before Using
Using
Using the
the
the
Equipment
Equipment
Equipment
The motor is pre-filled with oil. Before using the
equipment, replace the shipping plug with the vented
fill cap (P) that is included with the motor.
Figure 5 Sightglass and Oil Fill Cap
Power
Power
Power Supply
Supply
Supply Requirements
Requirements
Requirements
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
National, State and Local safety and fire codes.
See Table 1 for power supply requirements. The
system requires a dedicated circuit protected with a
circuit breaker.
Table
Table
Table 1
1
1 ... Power
Power
Power Supply
Supply
Supply Specifications
Specifications
Specifications
Model*
Model*
Model*
Voltage
Voltage
Voltage
Phase
Phase
Phase
Hz
Hz
Hz
kVA
kVA
kVA
EM001x
100–130
/200–240
Vac
1
50/60
1.4
EM002x
200–240
Vac
1
50/60
2.9
* The last digit of the Model No. varies. See the
Models
Models
Models tables on pages 3–6.
Hazardous
Hazardous
Hazardous Area
Area
Area Cabling
Cabling
Cabling and
and
and Conduit
Conduit
Conduit
Requirements
Requirements
Requirements
Explosion
Explosion
Explosion Proof
Proof
Proof
All electrical wiring in the hazardous area must be
encased in Class I, Division I, Group D approved
explosion-proof conduit. Follow all National, State,
and Local electric codes.
A conduit seal (D) is required within 18 in. (457 mm)
of the motor for the US and Canada.
All cables must be rated at 70°C.
Flame
Flame
Flame Proof
Proof
Proof (ATEX)
(ATEX)
(ATEX)
Use appropriate conduit, connectors, and cable
glands rated for ATEX II 2 G. Follow all National,
State, and Local electric codes.
All cable glands and cables must be rated at 70°C.
10
3A2526L
All manuals and user guides at all-guides.com