308225
6
Model Charts
Pressure and Ratio Ratings for Bulldog Pumps
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of over-pressurizing a component, which can result in an explosion and serious injury, never
operate the system at a working pressure higher than the lowest rated component in the system. All fluid side
components, such as dispensing valves; regulators; and hoses, must have a working pressure equal to or
greater than the pressure given in Column B for each pump model.
Column A gives the maximum pump fluid output pressure.
Column B gives the minimum working pressure required for all system components, based on the automatic relief
valve settings. Components included by Graco with the models listed meet or exceed this requirement.
Models with Two Displacement Pumps
A
B
Mix
Model No.
Maximum Pump
Fluid Output
Pressure
*
At Maximum
Air Pressure
Of:
Minimum
Component
Working Pressure
Normal
Pressure
Ratio
(Fl id t Ai )
Nominal
Flow
Volume
@ 40 cpm
Mix
Ratio
Bare
Wall
Stand
psi
MPa, bar
psi
MPa, bar
psi
MPA,
bar
(Fluid to Air)
gpm
lpm
1:1
231897
231836
231865
3000
21, 207
86
0.6, 6
3000
21, 207
34.7
1.8
6.8
Models with Three Displacement Pumps
A
B
Mix
Model No.
Maximum Pump
Fluid Output
Pressure
*
At Maximum
Air Pressure
Of
Minimum
Component
Working Pressure
Normal
Pressure
Ratio
(Fl id t Ai )
Nominal
Flow
Volume
@ 40 cpm
Mix
Ratio
Bare
Wall
Stand
psi
MPA, bar
psi
MPa, bar
psi
MPA,
bar
(Fluid to Air)
gpm
lpm
2:1 231908
231847
231876
2320
16, 160
100
0.7, 7
2900
20, 200
23.2
2.7
10.1
2:1 231910
231849
231878
3000
21, 207
86
0.6, 6
3600
25, 248
34.7
1.8
6.7
3:1 231912
231851
231880
2610
18, 180
100
0.7, 7
2900
20, 200
26.1
2.4
8.9
4:1 231915
231854
231883
2780
19, 192
100
0.7, 7
2900
20, 200
27.8
2.2
8.4