308225
18
Flushing
If this is a first time flush . . .
12. Repeat the flushing procedure using a solvent
compatible with the fluid you are going to
dispense.
When you are done flushing . . .
13. Remove the solvent supply from the feed pumps.
Operate the pumps slowly to push all the solvent
out of the lines, then stop the pumps.
If you are not going to use the system . . .
14. Close all air regulators, master air valves and fluid
shutoff valves. Follow the
Pressure Relief Proce-
dure
on page 19.
WARNING
INJECTION HAZARD
To reduce the risk of serious injury from fluid injec-
tion or fluid splashing, always close the air valve
(A4) to the solvent pump before opening the fluid
drain valves (P2) to relieve system pressure. This
will reduce the risk of excessive pressure buildup in
the opposite component hose and fittings.