Installation
3A8600B
13
Install Feed Tubes, HV-2000b
and HV-9500b
NOTE:
Feed tubes and syringe brackets are sold
separately. See
on page 28.
Rubber Feed Tube
1. Install the syringe bracket using the two screws
included to attach to the Jet.
2. Attach the feed tube to the outlet of the syringe.
3. Push the rubber feed tube over the barb of the
nozzle plate (AA).
4. Secure the syringe to the bracket by tightening the
thumbscrew.
Metal Feed Tube
NOTE:
A tilted face seal nozzle plate (top) (AD) is
required when using a metal feed tube.
1. Remove the lower syringe bracket from the syringe
bracket.
2. Install the face seal o-ring (included with nozzle
plate kit) into the recess on the tilted face seal
nozzle plate (top) (AD).
3. Attach the metal feed tube to the tilted face seal
nozzle plate (top) (AD) using the included fasteners.
Torque the fasteners to 0.9 N•m (8.0 lbf-in.). An
optional torque wrench is available for this purpose.
F
IG
. 11
F
IG
. 12
Syringe
Outlet
Barb
Rubber Feed Tube
Syringe
Thumbscrew
F
IG
. 13
F
IG
. 14
Syringe
Bracket
Lower Syringe
Bracket
Metal Feed
Tube
O-Ring
AD
Summary of Contents for Advanjet 26B951
Page 21: ...Parts 3A8600B 21 Parts HV 2000b WL D...
Page 23: ...Parts 3A8600B 23 HV 9500b WL D...
Page 25: ...Parts 3A8600B 25 HM 2600b WL D...