Operation
3A8503C
19
Pump Status LEDs
The Transfer Pump Controller (TPC) uses five LEDs to communicate the current status of the pumps and TPC. The
two LEDs on the top relate to the electric motor status (A on the left, B in the center). The three LEDs on the bottom
right are the TPC status LEDs.
LED Status Definitions
LED
Conditions
Description
A/B Electric
Motor Status
LEDs
Off
No AC Power Detected
Red and Blue
Startup
Purple
Idle
Blue
On:
• 1 flash for top changeover
• 2 flashes for bottom changeover
Red
Error
TPC Status
Green Solid
Low voltage power applied to module
Yellow Flashing
Active communication
Red Steady Flashing
Software update in progress
Red Random Flashing or
Solid
Module error exists
TPC Status
A/B Motor
Green
Yellow
Red
B Blue
A Blue
Summary of Contents for 26D000