Appendix B - ADM Setup Screens Overview
60
3A2797ZAA
Mix Head Operating Details Screen
This screen allows the user to define the mix head
operating parameters.
•
Low Pressure Circulation:
The percentage of set
-
point, 10%-90%, at which the system will run
during low pressure circulation.
•
Pre-Dispense Circulation:
The time for which the
system will circulate at high pressure prior to dis
-
pensing when the dispense command is triggered
while the system is in low pressure circulation.
•
Post-Dispense Circulation:
The time duration that
the system will remain in high pressure circulation
after a dispense before dropping into low pressure
circulation. Entering “0” disables the post-dispense
time.
Press
System Screen 3
This screen allows the user to edit the labels for the A
(Red) and B (Blue) sides of the machine. The labels set
for the A (Red) and B (Blue) sides of the machine are
displayed throughout the screens. Labels are limited to
five characters.
To edit a label:
1. Press
.
2.
To edit the A (Red) label,
press .
To edit the B (Blue) label,
press the down arrow
then press . The keyboard will appear on the
on page 61.
The pressure imbalance setting is set from this screen.
Pressure imbalance is the allowable difference in pres
-
sure between the two materials before an alarm is trig
-
gered. The input range is 145-2000 psi (1-14 MPa,
10-138 bar).
The flowmeter types are defined on this screen. The
ratio deviation value is the allowable percentage before
the machine displays a pop-up notification. The ratio
alarm value is the allowable percentage difference
before the machine will stop a dispense.
The ratio displayed between chemicals can be changed
between blue or red, allowing either chemical to be dis
-
played as a ratio to 1.
This screen allows the user to enter material specific
gravities.
Pressure
Imbalance
Setting