Appendix G - Communications Gateway Module Installation Kit
110
3A2797ZAA
183
Set or Read
Register
“Configurable Data
Command 2”
Assignment (Output
instance 9, O104 –
O119)
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Write
184
Read
185
Set or Read
Register
“Configurable Data
Command 3”
Assignment (Output
instance 10, O120 –
O135)
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Write
186
Read
187
Set or Read
Register
“Configurable Data
Command 4”
Assignment (Output
instance 11, O136 –
O151)
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Write
188
Read
200
Mixed Material in
Current or Last
Dispense
Sum of Blue and Red Materials Dispensed (In 0.01 CC or 0.01
Gram units)
Read
202
Blue Material in
Current or Last
Dispense
(In 0.01 CC or 0.01 Gram units)
Read
204
Red Material in
Current or Last
Dispense
(In 0.01 CC or 0.01 Gram units)
Read
206
Mixed Material
Resettable Counter
Sum of Blue and Red Resettable Counters (In 0.01 CC or 0.01
Gram units)
Read
208
Blue Material
Resettable Counter (In 0.01 CC or 0.01 Gram units)
Read
210
Red Material
Resettable Counter (In 0.01 CC or 0.01 Gram units)
Read
212
Pump Resettable
Counter
(in pump cycles)
Read
213
Reset All Resettable
Material Counters
Will set all the resettable counters to 0. System must be idle
(Pumps NOT moving) for this command to execute.
Read
220
Mixed Material Total
Counter
Sum of Blue and Red material dispensed from HFR or NVH (In 1
CC or 1 Gram units)
Write
222
Blue Material Total
Counter
Sum of Blue material dispensed from HFR or NVH (In 1 CC or 1
Gram units)
Read
224
Red Material Total
Counter
Sum of Red material dispensed from HFR or NVH (In 1 CC or 1
Gram units)
Read
226
Total Pump Cycle
Counter
Total number of pump cycles for the NVH/ HFR system.
Read
Data Exchange
Pointer
Designation
Description
Comments, Data Element Descriptions
Read/
Write