Operation
10
312668ZAC
Operation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Turn off power supply to the pump.
2. Trigger the dispense valve into a grounded waste
container to relieve pressure.
3. Open any bleed-type master air valves and fluid
drain valves in the system.
4. Leave the drain valve open until ready to pressurize
the system.
LDP5 Meter Setup
Locking and Unlocking the Trigger
To lock the trigger (F
. 8), press on the part of the
trigger that has the textured grip until it clicks into the
locked position.
To unlock the trigger (F
. 9), press on the smooth part
of the trigger until it clicks out of the locked position.
When the trigger is released, the fluid flow stops.
In Auto mode, the unit stops dispensing when the
entered amount has been dispensed.
In Manual mode, the trigger does not automatically
unlock; it must be unlocked manually.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, and
splashing fluids, follow the Pressure Relief Procedure
when you stop dispensing and before cleaning,
checking, or servicing the equipment.
F
IG
. 8
F
IG
. 9
ti11349a
Locked Position
ti11348a
Unlocked Position