background image

Installation 

4

309930C

13. Strip 9/16 in. of insulation with 8-gauge wire stripper 

from both sides.

14. Inspect wires. If not black or in burnt condition, con-

tinue to step . If wires appear black or in burnt condi-
tion, repeat step 13. Do not exceed 6 in.

17. Slide shrink tube over splice.

18. Using a heat gun or hair dryer, heat shrink tubing 

around splice. If neither is available, wrap entire 
length of shrink tubing with electrical tape.

19. Slide transformer back and install bolts to bottom.

20. Replace Reactor front panel.

12. Take larger 8-gauge wires and cut pins from both 

sides.

15. Install shrink tube over one end.

Wire

Cut wire

Male pin

Wire

Cut wire

Female pin

Shrink tubing

Wire

Wire 

16. Install splice between the two wires and tighten 

screws. 

Wire

Shrink

Splice

Wire

tubing