Removal 

2

309930C

Removal

Use F

IG

. 1 for the following instruction.

2.

Remove Reactor front cover.

3.

Remove two bolts holding transformer to frame and 
slide forward for access.

4.

Disconnect black, plastic, 3-pin connectors going 
from back of transformer to circuit board on the left. 
There are red wires on one side and black on the 
other.

5.

Loosen terminal screws one and two at rear of white 
terminal block (located at left of transformer wire tap 
terminal), and pull out black wires coming from back 
of transformer.

6.

From the top left of transformer, remove the two 
screws and nuts and remove white terminal block.

7.

From connector (F), remove and discard clamp (B).

8.

From connector (F), remove 8-gauge wire #3 (E).

9.

Remove and discard connector (F), wires, and white 
terminal block.

10. From connector (G), remove and discard clamp (A).

11. From connector (G), remove all three red wires.

12. Discard connector (G).

WARNING

Repairing this equipment requires access to parts 
which may cause electric shock or other serious injury 
if work is not performed properly. Read warnings in 
Reactor Repair manual. Be sure to shut off all power 
to the equipment before repairing. 

1.

Turn main power OFF 

. Disconnect power 

supply.

WARNING

Wait 5 min for stored voltage to discharge (E-30 and 
E-XP2 models only).

F

IG

. 1: Removing transformer

Discard

To circuit board

To white 
terminal block

E

B

A

G

F

Black wires

Red wires

TI5691A