![background image](http://html1.mh-extra.com/html/graco/248113/248113_instructions-manual_2253114002.webp)
Removal
2
309930C
Removal
. 1 for the following instruction.
2.
Remove Reactor front cover.
3.
Remove two bolts holding transformer to frame and
slide forward for access.
4.
Disconnect black, plastic, 3-pin connectors going
from back of transformer to circuit board on the left.
There are red wires on one side and black on the
other.
5.
Loosen terminal screws one and two at rear of white
terminal block (located at left of transformer wire tap
terminal), and pull out black wires coming from back
of transformer.
6.
From the top left of transformer, remove the two
screws and nuts and remove white terminal block.
7.
From connector (F), remove and discard clamp (B).
8.
From connector (F), remove 8-gauge wire #3 (E).
9.
Remove and discard connector (F), wires, and white
terminal block.
10. From connector (G), remove and discard clamp (A).
11. From connector (G), remove all three red wires.
12. Discard connector (G).
WARNING
Repairing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Read warnings in
Reactor Repair manual. Be sure to shut off all power
to the equipment before repairing.
1.
Turn main power OFF
. Disconnect power
supply.
WARNING
Wait 5 min for stored voltage to discharge (E-30 and
E-XP2 models only).
F
IG
. 1: Removing transformer
Discard
To circuit board
To white
terminal block
E
B
A
G
F
Black wires
Red wires
TI5691A
Summary of Contents for 248113