background image

Instructions

Hydraulic Fluid 
Controls

308395D

EN

Regulates hydraulic pressure and flow when used with Graco’s Dyna-Star

 and 

Power-Star

 hydraulic-powered lubricant pumps. For professional use only. 

Model 236864

Used with Dyna-Star

1500 psi (10.5 MPa, 105 bar) 

Maximum Working Pres-

sure
3 gpm (11 liters/min) Maximum Flow Rate

Model 236865

Used with Power-Star

1500 psi (10.5 MPa, 150 bar) 

Maximum Working Pres-

sure
12 gpm (45 liters/min) Maximum Flow Rate

Important Safety Instructions

Read all warnings and instructions in this 
manual. Save these instructions. 

Hydraulic fluid controls are designed to control 
hydraulic fluids only in a hydraulic power system. Any 
other fluids can cause unsafe operating conditions 
and results in component rupture, fire, or explosion 
which could result in serious injury, including fluid 
injection.

Model 236865

Model 236864

 

 

Summary of Contents for 236864

Page 1: ...del 236865 Used with Power Star 1500 psi 10 5 MPa 150 bar Maximum Working Pres sure 12 gpm 45 liters min Maximum Flow Rate Important Safety Instructions Read all warnings and instructions in this manu...

Page 2: ...rags and spilled or open containers of solvent and gasoline Do not plug or unplug power cords or turn lights on or off when flammable fumes are present Ground all equipment in the work area Use only g...

Page 3: ...diately with genuine manu facturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is...

Page 4: ...se only electrically conductive hoses Hydraulic Power Supply and Air Compressor follow manufacturer s recommendations Any pails used when flushing use only metal grounded pails when flushing Make firm...

Page 5: ...eds contact your Graco Representative Pressure Regulation The hydraulic fluid control pres sure reducing valve J reduces the hydraulic oil pres sure to the operating pressure required for application...

Page 6: ...st be kept clean at all times to reduce the risk of damaging the reciprocator hydraulic power supply To reduce the risk of over pressurizing the hydraulic reciprocator which could cause a rupture and...

Page 7: ...na Star pump Never exceed 1500 psi 10 5 MPa 105 bar Maxi mum Outlet Pressure from the control when used with a 1 1 Power Star pump Be sure all accessories added to the reciprocator power supply side o...

Page 8: ...ssure reducing valve J 3 Clean the pressure reducing valve J with a com patible solvent 4 Install the pressure reducing valve in the control 5 Try the system with the clean valve Follow the Starting t...

Page 9: ...djust pressure with the pres sure reducing valve Clogged valve Clean the pressure reducing valve Insufficient hydraulic power supply pressure Adjust the hydraulic power supply pressure If problem rema...

Page 10: ...104 112567 GAUGE pressure fluid 1 105 112578 VALVE ball 1 106 112581 SWIVEL union 90 1 107 112705 SWIVEL union 90 1 108 112707 ADAPTER male 1 109 112708 ADAPTER male 1 110 112715 HOUSE couple 3 ft 2...

Page 11: ...uid 1 104 112579 VALVE ball 1 105 112580 SWIVEL union 90 1 106 112705 SWIVEL union 90 1 107 112706 SWIVEL union 90 1 108 112708 ADAPTER male 1 109 112709 ADAPTER male 1 110 112715 HOSE coupled 3 ft 2...

Page 12: ...dB A Dimensions See Below Hydraulic Fluid Controls Power Star Maximum fluid working pressure 1500 psi 10 5 MPa 105 bar Pressure adjusting range 300 1500 psi 2 0 10 5 MPa 20 105 bar Flow setting 12 gp...

Page 13: ...Notes 308395D 13 Notes...

Page 14: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANT...

Reviews: