background image

Operation

307637S

5

Operation

 

1.

Start the pump. See instruction manual 307906, 
supplied.

2.

To dispense fluid and adjust fluid flow from the 
valve, start with the air supply turned off at the regu-
lator (20). Hold the valve handle (1a) in the down 

position to open the valve. Slowly open the regulator 
until the desired fluid flow is obtained. Air pressure 
of 30-40 psi (0.21-0.28 MPa, 2.1-2.8 bar) is recom-
mended to provide sufficient fluid flow without 
splashing. 

To use the electronic meter, see instruction manual 
308687, supplied, for detailed operating instruc-
tions.

Maintenance 

Electronically Metered Models 
Only

For electroniccaly metered models, see instruction man-
ual 308687, supplied.

Troubleshooting

Check all possible problems and causes before disas-
sembling gun.

Problem

Cause

Solution

Valve will not dispense fluid

Pump is not operating

Check pump. See manual 307906

Valve diffuser is clogged

Remove and clean valve diffuser

Strainer, if used, is clogegd

Remove and clean strainer

Electronic meter is malfunctioning

Replace dispense meter. See man-
ual 308687

Fluid flow from dispense valve is low 
or irregular

Pump is malfunctioning

Check pump. See manual 307906

Valve diffuser is clogged

Remove and clean valve diffuser

Strainer, if used, is clogged

Remove and clean strainer

Leakage at valve seat

Valve seal is worn or damaged

Replace

Valve spring is weak or broken

Replace

Fluid meter registers incorrectly or 
not at all

Electronic control is malfunctioning

Replace. See manual 308687

Summary of Contents for 222602

Page 1: ...e lubricants For professional use only Model 239702 Pump with gallon quart liter Electronic Meter 100 psi 0 7 MPa 7 bar Maximum Working Pressure Model 222602 Unmetered pump 100 psi 0 7 MPa 7 bar Maxim...

Page 2: ...d cause serious injury Follow the Pressure Relief Procedure when you stop spraying dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equ...

Page 3: ...lvents or flu ids containing such solvents Many other fluids may contain chemicals that can react with aluminum Contact your material sup plier for compatibility PERSONAL PROTECTIVE EQUIPMENT Wear app...

Page 4: ...he pump in the bung hole of a fluid supply container Screw the bung adapter A tightly into the hole Raise the pump about 1 2 inch 12 mm from the bottom of the container Tighten the bung adapter screw...

Page 5: ...ee instruction man ual 308687 supplied Troubleshooting Check all possible problems and causes before disas sembling gun Problem Cause Solution Valve will not dispense fluid Pump is not operating Check...

Page 6: ...usting nut 1c upward until a small gap 0 040 in maximum exists between the handle 1b and the valve housing 1k when the valve is reassembled Reinstall the handle on the stem Reinstall the pin NOTE Clea...

Page 7: ...Notes 307637S 7 Notes...

Page 8: ...ousing threads Press fit Turn nut 1c upward until a small gap 0 040 in max exists between the handle 1b and the housing 1k Step 2 under maintenance Ref Part Description Qty 101 222103 PUMP see 307906...

Page 9: ...Parts 307637S 9 Technical Data See manual 308687 for electronic meter technical data See manual 307906 for pump technical data 13 9 14 18 12 101 20b 20c 20a 20d 20g 20e 20f 16 11 22 1p 1 1n 1p 1n...

Page 10: ...f the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Reviews: