background image

Warnings 

2

307637S

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific 
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where 
applicable.

WARNING

FIRE AND EXPLOSION HAZARD

 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps. 

Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment 
until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause 
serious injury.

Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, 
checking, or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD

 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request MSDS from distributor or retailer.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Summary of Contents for 222602

Page 1: ...e lubricants For professional use only Model 239702 Pump with gallon quart liter Electronic Meter 100 psi 0 7 MPa 7 bar Maximum Working Pressure Model 222602 Unmetered pump 100 psi 0 7 MPa 7 bar Maxim...

Page 2: ...d cause serious injury Follow the Pressure Relief Procedure when you stop spraying dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equ...

Page 3: ...lvents or flu ids containing such solvents Many other fluids may contain chemicals that can react with aluminum Contact your material sup plier for compatibility PERSONAL PROTECTIVE EQUIPMENT Wear app...

Page 4: ...he pump in the bung hole of a fluid supply container Screw the bung adapter A tightly into the hole Raise the pump about 1 2 inch 12 mm from the bottom of the container Tighten the bung adapter screw...

Page 5: ...ee instruction man ual 308687 supplied Troubleshooting Check all possible problems and causes before disas sembling gun Problem Cause Solution Valve will not dispense fluid Pump is not operating Check...

Page 6: ...usting nut 1c upward until a small gap 0 040 in maximum exists between the handle 1b and the valve housing 1k when the valve is reassembled Reinstall the handle on the stem Reinstall the pin NOTE Clea...

Page 7: ...Notes 307637S 7 Notes...

Page 8: ...ousing threads Press fit Turn nut 1c upward until a small gap 0 040 in max exists between the handle 1b and the housing 1k Step 2 under maintenance Ref Part Description Qty 101 222103 PUMP see 307906...

Page 9: ...Parts 307637S 9 Technical Data See manual 308687 for electronic meter technical data See manual 307906 for pump technical data 13 9 14 18 12 101 20b 20c 20a 20d 20g 20e 20f 16 11 22 1p 1 1n 1p 1n...

Page 10: ...f the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Reviews: