Installation
6
307883L
Typical Installation for Stationary Mountings
NOTE:
The typical installation shown in F
. 3 is only an installation guide; it is not an actual system design. Contact
your Graco distributor for assistance in designing a system to suit your needs. See X on page X for the Mobile
Mounting installation.
A
Fluid Dispense Line
B
Pump
C
Ground Wire
D
Pump Runaway Valve
E
Air Lubricator
F
Bleed-type Master Air Valve
G
Air Regulator
H
Air Filter
J
Main Air Line
Stationary Mounting Layout
•
Plan the layout for easy operator access to the
pump air controls, sufficient room to change drums,
and a secure platform.
•
For ease in changing drums, install a pump eleva-
tor.
Open Drum, Cover Mounted Pumps
1. Remove the original drum cover.
2. Place the cover (3) on the drum and fasten it with
the screws and washers provided.
3. Carefully guide the pump riser tube through the
mounting gasket.
Closed Bung-Type Drum
1. Loosen the drum cover vent plug and remove the
bung cover.
2. Install the pump through the bung hole until the
pump foot valve is 1/2 inch (13 mm) off the drum
bottom. Tighten the bung adapter.
F
IG
. 3
$
%
&
'
(
)
*
+
-
LQPP